The air filter for the RG-S12000 shall be cleaned periodically (generally once every three months) by dry
cleaning or washing. Do not rub during the cleaning or washing and flat dry after the cleaning or washing.
Power Supply Maintenance
When the power supply fails, you only need to disconnect the power cable, loosen the two panel screws on the power
module, unplug the power module, replace it with a good one, and tighten the panel screws, and then connect the power
cables.
Replacing Fuses
To replace the old fuse wire with the correspondent new one, please contact the technical support representatives of
Ruijie Networks. The following table lists the specifications for the module fuses.
Model
Fuse slot number
Fuse specification
M12006-FAN I
F1
F 10A/125V
M12010-FAN I
F1
F 10A/125V
M12000-CM F1
F
10A/125V
M12000-CM III
F1
F 10A/125V
M12000-02XFP24SFP/12GT-EA F1
F
5A/125V
M12000-24SFP/12GT-EA F1
F
5A/125V
M12000-48GT/4SFP-EA F1
F
10A/125V
F1 F
10A/125V
M12000P-48GT/4SFP-EA
F2, F3
F 15A/65V
M12000-24GT/12SFP-EA F1
F
5A/125V
M12000-04XFP-EA F1
F
5A/125V
M12000-48XS-DA
F1, F2
F 10A/125V
M12000-16XS-DA
F1, F2
F 10A/125V
M12000-04QXS-DA
F1
F 10A/125V
RG-WALL 1600-B-DC
F1
F 10A/125V
RG-WALL 1600-B-U
F1
F 10A/125V
M12000-WS F1
F
10A/125V
SECM M12000-NMM
F1
F 5A/125V