For the host management and service modules, air flows across the chassis from right inlets to back outlets. For the
power supply modules, air flows in from front inlets and out from back outlets. Host management and service modules are
separated from power supply modules by a division board, which creates two separated air channels. Airflow directions
are shown in the above figure. Four fans of 120 x 120 x 38 are used to are used to draw air for convection and heat
dissipation..
The chassis should be mounted in a place with sufficient space for air circulation. Sufficient space (10 cm at
least) must be reserved at the air intakes and exhaust vents for ventilation.
RG-S12010
Specifications
Model RG-S12010
Module Slot
10 (two for management engine modules)
Management
engine module
M12000-CM
M12000-CM III
Service module
M12000-02XFP24SFP/12GT-EA
M12000-24SFP/12GT-EA
M12000-24GT/12SFP-EA
M12000-48GT/4SFP-EA
M12000P-48GT/4SFP-EA
M12000-04XFP-EA
M12000-48XS-DA
M12000-16XS-DA
M12000-04QXS-DA
SECM M12000-NMM
RG-WALL 1600-B-DC
RG-WALL 1600-B-DE
RG-WALL 1600-B-U
M12000-WS
Hot swapping
Supported
Management Supported