Figure 3-6 Grounding schematic diagram of RG-S12000
1)
Release the nut on the grounding pole of the equipment.
2)
Lock the terminal of the grounding cable to the grounding pole.
3)
Tighten the nut with a cross screwdriver.
4)
Connect the related terminals according to the above steps.
5)
There are grounding points of the equipment on both sides of the back of equipment, you can choose them
according to the actual condition.
To guarantee the security of the person and the device, the RG-S12000 must be well-grounded. The
grounding resistance shall be less than 1
Ω
.
A service person shall check whether or not the socket-outlet from which the equipment is to be powered
provides a connection the building protective earth. If not, the service person shall arrange for the installation
of a protective earthing conductor from the separate protective earthing terminal to the protective earth wire
in the building.
The socket-outlet shall be installed near the equipment and shall be easily.
When installing the unit, always make the ground connection first and disconnect it last.
The cross-sectional area of protective earthing conductor shall be at least 2.5mm2(12AWG).
Connecting the AC Power Supply to the Power Module
Connect AC power cables according to the ID and position instruction on the RG-PA1200I and RG-PA2000I panel of the
AC power module.
Precautions
Before connecting the power supply, you must verify that the external power supply matches the power module
installed with this equipment.
Before connecting the power cable, be sure that the switch of the power module is at the OFF position.
The 16A power cable with a standard 3-pin connector should be used for connection.