e.
Check Multi-cutter – drive bolt for ease of operation and the end clearance and make sure, that
the running surfaces of the bearings show no sign of having plane surfaces.
f.
Check the cam rollers of all Multi-cutter frames for ease of operation and make sure, that the
running surfaces of the bearings show no sign of having plane surfaces.
g. Check all safety limit switches and safety covers according to the safety instruction.
h.
Undertake a visual check of the complete machine body. Obvious changes to the surface
have to be rectified immediately.
5.2 Regular service
Regular service on the machine has to be performed every 2000 operating hours or at least
once a year, in case that the machine has not been running for 2000 hours.
The regular service consists of the following steps:
a. Exchange of the Multi-cutter drive bolts
b. Exchange of the LC unit with battery set of the fully automatic grease dispensers.
c. Smoothing and readjusting the sectioning blade.
d. All the maintenance work according to ”Regular maintenance”
e. Check the main clutch and the free wheel bearings.
f. Check the overload clutch of the pre-compacting plunger.
g. Check the linear drive for the forward feed adjustment.
h. Check the safety functions.
i. Use operating panel to read error protocol and examine the errors.
K. Perform a test run with the machine open, using the Bierschinken program.
Summary of Contents for SR1 turbo