Bosch Security Systems, Inc.
User Manual
F.01U.193.294
Rev. 10
APPENDIX A
Boot Loader Reset
Boot Loader Reset - BLR Button
The
BLR
is used to upload new firmware to a keypanel with a corrupt/bad image installed.
There are two (2) ways you can download firmware for the keypanel:
•
Run the boot loader from the keypanel, see “Run The Boot Loader” on page 173.
•
Enable the boot loader on the keypanel and download the firmware using AZedit, see “Enable The Boot
Loader On The Keypanel (v 1.1.0 and later)” on page 177 (v 1.1.0 and later).
NOTE:
The instructions provided below are shown using the KP 32 CLD, but are applicable for all CLD family
keypanels.
Run The Boot Loader
To
run the boot loader
, do the following:
1.
Power
off
the KP CLD keypanel.
2.
Verify the KP CLD is powered
off
, but still connected to the frame.
3.
Using a screwdriver, press the
BLR
button located on the back of the keypanel.
4.
While the BLR button is pressed, connect the
power cord
to the keypanel.
KP 32 CLD - Boot Loader Waiting for Download... appears in the display window
.
Summary of Contents for DKP 16 CLD
Page 4: ...Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 4 KP32CLD ...
Page 62: ...52 Basic Operation KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 154: ...144 KP 32 CLD Menu System KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 186: ...176 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 192: ...182 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 222: ...212 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 226: ...216 KP32CLD Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 ...
Page 231: ...KP32CLD 221 Bosch Security Systems Inc User Manual F 01U 193 294 Rev 10 Notes ...