JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 37 of 48
Downloading Data
Data Stored
The following data is stored for each fusion that the processor performs. The data stored in the processor can
be downloaded wirelessly via Bluetooth. The data is output in a binary format that is compatible with a free
macro-enabled Excel Spreadsheet available from JACKMAN FUSION EQUIPMENT.
Field
Description
SN
The serial number of the processor.
Fusion #
The fusion number.
User Fusion #
The user resettable fusion counter.
Date
Date and time the fusion was performed.
Cal Due
The date that the calibration is due.
Cal Req.
TRUE if the calibration date was expired when the fusion was completed.
Firmware
The firmware version of the processor loaded when the fusion was performed.
Result
The resulting error code.
Mode
The mode used for entering the fusion parameters.
Fitting
The fitting manufacturer type and size.
Control
The requested fusion output voltage.
Temp
The ambient temperature at the time of the fusion.
Nom. Time
The requested fusion time.
Comp Time
The fusion time after temperature compensation was applied.
Actual Time
The actual time the fitting was fused.
Mea Res
The resistance of the fitting specified in the barcode.
Tolerance
The specified resistance tolerance.
Mea Res Pre
The actual measured resistance of the fitting before the fusion.
Mea Res Post
The actual measured resistance of the fitting after the fusion.
Cooling time
The cooling time of the fitting specified in the barcode.
Input Volts
The measured generator voltage taken before the fusion.
High Volts
The highest measured generator voltage during the fusion.
Low Volts
The lowest measured generator voltage during the fusion.
Wave
The type of supply waveform identified during the fusion (Sine or Square).
Frequency
The measured generator frequency made before the fusion started.
High Freq
The highest measured generator frequency during the fusion.
Low Freq
The lowest measured generator frequency during the fusion.
L Out V
The lowest measured output voltage during the fusion.
H Out V
The highest measured output voltage during the fusion.
L Out A
The lowest measured output current during the fusion.
H Out A
The highest measured output current during the fusion.
Ah Out
The total number of Amp-Hours expended during the fusion.
Position
The GPS latitude and longitude at the time of the fusion.
Sat
The number of satellites used when determining the GPS fix.
Q
The GPS signal quality (0=no good, 1=GPS, 2=DGPS).
HDOP
GPS Horizontal Dilution of Precision.
Operator
The operator ID code if enabled.
Traceability
The pipe/fitting traceability codes if enabled.