JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 36 of 48
To CANCEL THE FUSION:
1.
Press the
STOP button
to cancel the fusion now. The processor will display a screen similar to the
following:
ERROR 102 RECEIVED
Resistance 16.578
Min:1.21 Max:1.78
Hold START to clear
2.
Press and hold the
START button
to clear the error code. Follow the prompts on the processor display.
See page 43 for information how to troubleshoot an Error Code 102.
To PERFORM SECONDARY CHECK:
1.
Press the
START button
to begin a Calculated Resistance check and attempt to continue the fusion.
The processor will begin the fusion process and display a screen similar following:
FUSION NUMBER: 00125
60 sec
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION
COULD RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
2.
If the Calculated Resistance check is successful, the fusion will proceed normally. When the fusion is
complete, a screen similar to the following will be displayed:
COOLING TIME: 5 min
Actual Fusion Time
60 sec
PRESS START
Press the
START button
to continue.
3.
If the Calculated Resistance check fails, the processor will display a screen similar to the following:
ERROR 102 RECEIVED
Resistance 16.578
Min:1.21 Max:1.78
Hold START to clear
Press and hold the
START button
to clear the error code. Follow the prompts on the processor display. See
page 43 for information how to troubleshoot an Error Code 102.