JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 23 of 48
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING MANUFACTURER’S RECOMMENDATIONS FOR FUSING THE ATTACHED FITTING
UNDER THE CURRENT AMBIENT CONDITIONS.
The processor will BEEP once per second and the text “PRESS START” on the bottom line of the display will
flash on and off.
Once you have verified that all measurements and parameters are correct, press the
START button
to begin
the fusion.
FAILURE TO VERIFY THAT THE FUSION INFORMATION IS CORRECT BEFORE STARTING A FUSION COULD
RESULT IN SIGNIFICANT DAMAGE TO PROPERTY, PERSONAL INJURY, AND/OR DEATH.
See page 24 for instructions on monitoring the progress of a fusion.