JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 18 of 48
After the Operator Traceability Data is entered, the processor will display the CONNECT FITTING screen. An
example of the CONNECT FITTING screen is shown below:
CONNECT FITTING
Temperature: +75° F
Gen: 120V 60.0Hz
On the CONNECT FITTING screen, the second line indicates the ambient temperature the processor is
measuring and will be used to modify the fusion time if required by the fitting manufacturer.
Check to make sure the temperature reading is accurate. If the processor has been in direct sunlight or has
been moved from a hot or cold environment, the temperature may not be correct. If the temperature
indicated is not correct, allow the processor time to adapt to the correct temperature, approximately 15-20
minutes.
The last line indicates the generator status. The voltage and the frequency are displayed. It is important that
the voltage measurement is within the allowable range and the frequency is stable.
See Specifications Table
on page 7.
Pressing and holding down the
UP Button
while the processor is at the CONNECT FITTING screen will show a
screen similar to the following.
1.2.3 SN:9720000
SW: ON 03 FC:0124
05/11/2018 15:30
CAL DUE
–
05/11/2021
This screen shows the following information:
•
Software version of the processor (In this case, version 1.2.3).
•
Processor serial number (In this case, 0000000).
•
SMART Scanner™ status (In this case, ON).
•
The number of fusions the processor has completed (In this case, 124).
•
The Date and Time (In this case, May 11, 2018 at 3:30 PM)
•
The date the processor will be due for calibration (In this case, May 11, 2021)
Release the
UP button
to return to the CONNECT FITTING screen.
To begin the fusion process, follow the instructions in the following section that corresponds to the fusion
method that you wish to perform.