JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 7 of 48
Specifications
Parameter
Value
Supply Voltage
97 VAC to 150 VAC
Supply Frequency
47 Hz to 70 Hz
Supply Waveform
Sine Wave or Square Wave
Maximum Supply
Current
30 Amps
Output Voltage
8 VAC to 48 VAC +/- 1.5%
Output Current
4 AAC to 60 AAC +/- 1.5% up to 48 volts output (80 AAC @ up to 42 VAC
output)
Size
22” x 14” x 9” (20.5” x 11.5” x 8.25” Case interior)
Weight
Approx 45 lbs
Duty Cycle
30%
Operating
Temperature Range
0°F to +140°F (-18°C to +60°C)
Operating Modes
Barcode, Manual, Manual Barcode
Output Cable Length
12 feet
Input Cable Length
12 feet
Downloading
Internal Bluetooth module for downloading fusion data to EF Utilities app.
Languages
English, French, Spanish
Fitting Adapters
Field Replaceable 90 degree (4.0mm and 4.7mm Included)
Environmental
Protection
IP54 Splash-Proof
Warranty
1 Year
Calibration Interval
3 Years
Scanning
Interchangeable Smart Scanner or Smart Scanner with GPS
GPS
Active when using a Smart Scanner with GPS
IEC Protection Class
Class 1 Grounded
Calibration/Service
Field calibration capable
AutoCal® Compatibility
This device is fully compatible with the AutoCal® field calibration system.