then there is a processor problem and it must be returned for service.
121
Invalid operator ID card
scanned.
Verify the system date is correct and, if so, contact the agency that
issued the Operator ID card.
122 Not an operator card.
Contact the agency that issued the Operator ID card.
123
The operator card scanned
does not contain operator
privileges for the functions
this machine is capable of
performing.
124
Current offset is out of
spec.
Processor must be returned for calibration. You cannot fuse if this error
is detected.
125
Resistor ID fusion cannot
be completed because the
value was not decoded
into a valid fusion time.
Verify that the fitting and the processor both support the Resistor ID
method. If so, the problem is with the fitting, the output cable, or the
processor calibration. If the problem persists with multiple fittings, the
processor will have to be returned for service.
130
The fitting was
disconnected before the
specified cooling time.
Do not disconnect the fitting before the manufacturer
’
s recommended
cooling time has expired.
131
An undefined error was
received before the fusion
time was completed.
Processor must be returned for service.
132
Processor supports voltage
control only and fusion
specified is not voltage
control.
Not all processors support current or energy control. Attach a fitting that
requires voltage control or contact an authorized representative
(See
page 15)
to see if an update is available for your processor.
138
The fitting was
disconnected before the
specified countdown time
elapsed.
Do not disconnect the fitting before the manufacturer
’
s recommended
countdown time has expired.
140
The fusion was shutoff to
protect the processor from
damage due to extremely
high fusion current.
This is typically caused when a direct short is made across the Output
Lead Ends. If there are no obvious problems with the fitting or the
output cable, then the processor will need to be returned for service.
141
The ambient temperature
is too low to fuse fittings of
this type.
Same as Error 101.
142
The processor believes
that the same fitting was
fused twice.
Do not fuse a fitting more than two (2) times unless directed to do so by
the fitting manufacturer.
143 The fitting was
disconnected before the
Do not disconnect the fitting before the manufacturer
’
s recommended
heat soak time has expired.