105
Can’t maintain output
voltage.
Verify that the Output Lead Ends are clean, the power supply is sized
correctly for the fitting you are fusing, and the power supply is operating
correctly.
108
The power supply was shut
off during the previous
fusion.
This could be anything from an improperly sized generator to someone
switching the processor off during a fusion.
109
Referenced voltage out of
tolerance.
Processor must be returned for calibration. You cannot fuse if this error
is detected.
110
STOP pressed during
previous fusion.
Do not press the STOP button during the fusion unless in an emergency
situation.
111
Fusion complete with no
other errors.
There were no problems with this fusion.
112 Fitting disconnected.
Current drops close to 0 during the fusion. If the problem persists there
is more than likely an output cable problem and the processor should be
returned for service.
113
The calibration date has
expired.
Send the processor in for calibration.
114
There is no valid
calibration date set.
Send the processor in for calibration.
115
The processor is not
capable of outputting the
current required to fuse
this fitting.
As long as the fitting
’s
fusion requirements are within the specified
output range of the processor. This could be an output cable error or a
calibration error. Try cleaning the Output Lead Ends, if the problem
persists, the processor will need to be returned for service.
116
The processor is not
capable of outputting the
voltage required to fuse
this fitting.
117
Input voltage is out of
range and the fusion
cannot start.
Verify that the input voltage and frequency displayed on the CONNECT
FITTING screen are reasonable and within the range specified in the
Specification Table
(See page 7)
. If the parameters displayed differ
significantly from the actual input, then there is a processor problem and
it must be returned for service.
118
Frequency is out of range
and the fusion cannot
start.
119
Internal processor
temperature is out of
range.
Allow the processor to cool before fusing again. This error can be seen if
multiple large fittings are fused one after the other.
120
A time of 0 seconds for the
fusion was entered or
calculated.
This is more than likely a temperature measurement problem. Verify the
temperature displayed in the CONNECT FITTING screen is reasonable and
within the range specified in the Specification Table
(See page 7)
. If the
temperature displayed differs significantly from the actual temperature,