JACKMAN FUSION EQUIP
–
ELECTROFUSION PROCESSOR OPERATORS MANUAL - REV 0
Page 28 of 48
Operator ID
This setting controls the Operator Traceability functions. This option is different than Pipe/Fitting Traceability.
Pipe/Fitting Traceability is discussed below. Values
for Operator Traceability are “OFF”, “ON”, or “SCAN”
:
•
“OFF” disables the Operator Traceability function.
•
“ON” enables th
e Operator Traceability function.
•
“SCAN” enables the Operator Traceability function with a requirement to scan an ISO 12176
-3
compliant Operator ID Badge.
When Option 2 is highlighted, press the
START button
to select it. Use the
UP/DOWN buttons
to toggle
through available Operator Traceability function values. When the desired value is displayed, press the
START
button
to save.
To obtain operator barcodes, contact an authorized representative (See page 15).
Profiles
The Profiles setting currently has no function. The processor will beep twice if it accessed.
Calculated Resistance
This setting controls the Calculated Resistance option. Values for
Calculated Resistance are “OFF” or “ON.”
•
“OFF”
-
RECOMMENDED
: The processor always measures resistance using a lab quality 4-wire
measurement. This is the processor’s primary method of resistance measurement and is frequently
used during Quality Control testing by fitting manufacturers.
•
“ON” –
If a processor displays Warning Code 55 (see page 43), an operator has the option to perform a
secondary Calculated Resistance check. During this secondary check, the unit calculates a resistance
estimate based on fusion voltage and current.
DO NOT TURN CALCULATED RESISTANCE ON UNLESS A 4-WIRE MEASUREMENT FAILS.
TURNING ON CALCULATED RESISTANCE DOES NOT GUARANTEE THAT A FUSION WILL BE SUCCESSFUL.
BEFORE TURNING ON CALCULATED RESISTANCE, ALWAYS CONFIRM WITH THE FITTING MANUFACTURER
THAT IT IS AN ACCEPTABLE METHOD OF MEASUREMENT FOR THEIR SPECIFIED FITTING.
IT IS THE RESPONSIBILITY OF THE OPERATOR TO VERIFY THAT ALL THE INFORMATION DISPLAYED IS
CORRECT PER THE FITTING MANUFACTURER’S RECOMMENDATIONS FOR FUSING THE ATTACHED FITTING
UNDER THE CURRENT AMBIENT CONDITIONS.
When Option 4 is highlighted, press the
START button
to select it. Use the
UP/DOWN buttons
to toggle
between the Calculated Resistance values. When the desired value is displayed, press the
START button
to
save.
See page 35 for instructions how to operate the processor with Calculated Resistance.