This screen displays the following information:
•
The most recently measured voltage and current outputs of the processor.
•
The total energy expended during this fusion, in amp-hours (In this case, 0.085 amp-hours).
This
number increases during the fusion process as energy is expended.
•
The present measured voltage of the generator (In this case, 118 volts).
•
The current generator frequency. This number should remain relatively constant throughout the
fusion.
When the fusion is complete, the following screen will be displayed:
COOLING TIME 5 min
Actual Fusion Time
60 sec
PRESS START
This screen displays the following information:
•
The cooling time, if specified (In this case, 5 minutes).
•
The actual amount of time that the fitting was fused (In this case, 60 seconds).
Press the
START button
to continue.
After the fusion process has ended, the processor will prompt the operator to disconnect the Output Lead
Ends and will not recognize any other inputs until this task is complete.
If no errors were encountered during the fusion process, the following screen will be displayed:
DISCONNECT
OUTPUT LEADS
FUSION COMPLETED
Successfully
If errors were encountered during the fusion process, an Error Code Message will be displayed (see page 43
for a list of possible Error Codes), and the following screen will be displayed after the error message screen:
DISCONNECT
OUTPUT LEADS
FUSION NOT COMPLETE
Errors Encountered
After the Output Lead Ends are disconnected, the
Roughneck Electrofusion Processor
will return to
the
CONNECT FITTING screen and will be ready to accept information for the next fusion.
NOTE:
If Operator Traceability is enabled, remember that the Operator ID codes entered previously will remain
attached to any additional fusions until the power is shut off or until the information is changed by the
operator.