CrossOver 16 User Manual (v4.0)
Configuration • 2–5
the
Cancel
knob to return to the
Output
Sync
menu for further editing.
Note:
• You can reset the Output Reference Sync by
pressing the
Reset
knob on the second page of
the
Output Sync
menu.
Setting Analog Output Reference Color Framing
When the output reference (OSync) is set to an
analog format (NTSC/PAL), the color framing in the
subcarrier can be synced to the color framing of the
input reference. The input reference must also be set
to an analog format.
To Sync Output Reference Color Framing:
1.
Press
MENU
.
2.
Press the
REF
Wipe Pattern button.
3.
Press
NEXT >
NEXT
.
4.
Use the
ColFrm
knob to turn syncing of
color framing on or off.
•
NoSync
— Select this option to not have
color framing synced in the output reference
synced to the color framing in the input
reference.
•
Sync
— Select this option to have color
framing synced in the output reference synced
to the color framing in the input reference.
Note:
• Jitter on the color framing of the reference output
causes the analog reference output to reset in an
attempt to re-sync.
Aspect Ratio
The switcher supports both 4:3 and 16:9 aspect ratios
when running in the 480i/576i video format.
To change the aspect ratio:
1.
Press
MENU
.
2.
Press the
REF
Wipe Pattern button.
3.
Press
NEXT
until Aspect is displayed.
4.
Use the
Aspect
knob to select the desired
aspect ratio. You can choose from the following:
•
4:3
•
16:9
5.
Press the
Aspect
knob to save your
selection.
6.
Press the
Confrm
knob to commit the
change. Press the
Cancel
knob to discard
the change and return to the previous setting.
Note:
• The aspect ratio is locked to 16:9 when operating
in 720p or 1080i video formats.
Ancillary Data
Ancillary data is information such as closed
captioning or embedded audio. The switcher can be
configured to pass this data or strip it from the output
video. The following modes are available (each
mode differs depending on the video format of the
switcher as shown in Table 2.3):
•
Normal Strip
— Ancillary data is stripped from
both the horizontal and vertical blanking.
•
Normal Pass
— Ancillary data in the horizontal
and vertical blanking is passed unmodified.
•
Long Strip
— Ancillary data is stripped (and
replaced with black) from both the horizontal and
vertical blanking as well as some lines of active
picture.
•
Long Pass
— Ancillary data in the horizontal and
vertical blanking and some lines of active picture
are passed unmodified. This ensures data, such as
timecodes and closed captioning, remain intact
(480i/576i video format only).
To configure ancillary data parameters:
1.
Press
MENU
.
2.
Press the
SYSTEM
Wipe Pattern button.
3.
Press
NEXT
until
Anclry
is displayed.
MENU
NEXT
NEXT
MENU
NEXT
Table 2.3 Vertical Ancillary Data
Video Format
Last Line of Vertical Ancillary Data
Normal Pass/Strip
Long Pass/Strip
480i
19
21
576i
22
24
720p
25
25
1080i
20
20
MENU
NEXT
Summary of Contents for CrossOver 16
Page 1: ...Ross Video Limited CrossOver 16 Operator s Manual Software Issue 4 0...
Page 10: ......
Page 32: ...2 16 Configuration CrossOver 16 User Manual v4 0...
Page 84: ...8 4 Calibration and Diagnostics CrossOver 16 User Manual v4 0...
Page 92: ...9 8 Specifications CrossOver 16 User Manual v4 0...