G A L A X Y ® A U R O U R A L S C O N F I G U R A T I O N A N D S Y S T E M I N T E G R A T I O N G U I D E
74
Section 3 Management
3.1.13
ADAPTER Details
This screen shows a lot of information. It shows Ethernet ports, Fibre Channel ports, and
Infiniband Ports. (Note: In the example above, one Fibre client and one Infiniband client are
shown).
In the top table, we see the Ethernet ports which can be used to remotely manage the array.
The current port name and IP address are shown for each port. In the DHCP dropdown, “y”
indicates that DHCP is being used. If you wish to enable DHCP, change the dropdown to y,
clear the IP address and subnet mask on the right, then left-click on the Update button on the
left. If you wish to set a static IP address, change the DHCP dropdown to n, type the IP
address and subnet mask in the fields on the right, then left-click on the Update button on the
left.
The middle table shows information relating to Fibre channel. The model of each port is
shown, along with it's WWN#, the Link status, and link speed. The text field at the bottom
along with Update Optional FC Card Parameters is used to change special settings on the
Fibre Channel card within the array.
The bottom table shows Infiniband-related information. Going from left to right, you can see
the port number, physical state, port state, and data rate.
The Return to NumaRAID GUI Main Page link at the bottom is used to return to the
NumaRAID Main GUI screen.