RCP Technik GmbH & Co. KG, Tarpen 40/Gebäude 7b, D-22419 Hamburg
Hotline: +49 (0)6 31/3 42 84 49
8
4.3. Assembly of surveillance camera
Using the supplied wall fixing, the surveillance camera can be installed at a fixed location.
Note:
• Do not place surveillance camera directly next to electronic devices as this could produce interference. In case of
picture interference, test camera at another location.
• Select the installation site for the surveillance camera so that the lens is not exposed to sun light.
4.3.1. Install wall fixing
Hold the plate of the wall fixing containing holes against the surface of the selected installation site and mark the holes on
the surface, using a pencil.
To drill suitable holes, use a 6 mm masonry drill for dowels in stone or concrete surfaces or a 3 mm wood drill for timber
surfaces. After drilling the holes insert supplied wall plugs into holes so that they are flush with the surface. Secure wall
fixings with supplied bolts.
4.3.2. User data supplied with camera
Using the four bolts, secure the surveillance camera to the retaining plate of the wall fixing. Align the surveillance camera as
desired.
4.3.3. Complete camera assembly
Connect surveillance camera and PoE adapter using supplied LAN cable and plug it into the left LAN socket of the PoE adapter.
The surveillance camera is now connected to power. You can also use a LAN cable instead of WLANs to connect the camera
to your network. Plug a LAN cable into the right socket of the PoE adapter and connect it to the router. A LAN connection is
required for initial installation.