![Roland TrueVIS SG-300 User Manual Download Page 183](http://html1.mh-extra.com/html/roland/truevis-sg-300/truevis-sg-300_user-manual_1481445183.webp)
18 1
6
Troubleshooting
O ther P roblems
The P rinter Unit Doesn't Run
Is the p ower switched on?
Switch on the printer's main power, and then press the sub power
switch and make sure the sub power switch lights.
"
P . 2 4 " Tu r n i n g t h e P o w e r O n "
Is [ SETUP ] lit?
Output is not performed when [SETUP] is not lit. Lower the loading lever.
"
P . 5 5 " S t e p 6 : S t a r t i n g O u t p u t "
Is a cover op en?
Close the front, left, and right covers.
Is the top menu disp lay ed?
Top menu
W1100mm
If the top menu isn't displayed, output doesn't start even when data
is sent from the computer. To go to the top menu, press [MENU].
"
P . 5 5 " S t e p 6 : S t a r t i n g O u t p u t "
Is [ P AUSE] lit?
When [PAUSE] is lit, operation is paused. To resume, press [PAUSE].
[PAUSE] turns off and output resumes.
"
P . 7 4 " P a u si n g o r C a n ce
l i n g O u t p u t "
Is a message disp lay ed on
the screen?
"
P . 185 " A M e ssa
g e A p p e a r s"
"
P . 187 " A n E r r o r M e ssa
g e A p p e a r s"
Are the cables connected?
Connect the cables securely.
"
S e t u p G u i d e
Is the network routing ap -
p rop riate?
Check whether the network routing is appropriate. Try connecting
the computer and the machine to the same hub, or connecting
them directly using a crossover cable. If this makes it possible to
perform output, it means the problem may be in the network itself.
Are the network settings
correct?
If the cable connections are secure and no problem is found in
the network itself, make sure that the IP address and other such
settings are appropriate. The settings on both the machine and
the computer must be appropriate. Redo the settings, checking
to ensure that the IP address does not conflict with the IP address
for another device on the network, that the port setting for the
software RIP specifies the IP address set on the machine, that
the settings have no typing errors, and for other such problems.
"
S e t u p G u i d e
"
P . 162 " V i e w i n g S yst
e m I n f o r m a t i o n "
Did the sof tware RIP ex it
abnormally ?
Make sure the software RIP is running correctly, and then switch
the sub power switch off and back on.
"
Ro l a n d V e r sa
W
o r ks
Q u i ck
S t a r t G u i d e