Remote Commands for HRP UWB Measurements
R&S
®
VSE-K149
109
User Manual 1179.3315.02 ─ 01
Example:
EFR:IDN?
//Result: Rohde&Schwarz,FE44S,
1234.5678K00/123456,0.8.0
Usage:
Query only
[SENSe:]EFRontend[:STATe]
<State>
Activates or deactivates the general use of an external frontend for the application.
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
The frontend is disconnected. The application adapts the mea-
surement settings to the common settings supported by the
R&S
VSE.
ON | 1
The R&S
VSE allows you to configure and connect an external
frontend for the application. The application adapts the available
measurement settings to the connected frontend. The channel
bar indicates "Inp: ExtFe".
*RST:
0
Example:
EFR ON
Commands for Alignment
The following commands are required to align the connection after it has initially been
set up.
[SENSe:]EFRontend<fe>:ALIGnment<ch>?
......................................................................109
[SENSe:]EFRontend<fe>:ALIGnment<ch>:DATE?
.............................................................110
[SENSe:]EFRontend<fe>:ALIGnment<ch>:FILE
................................................................ 110
[SENSe:]EFRontend<fe>:ALIGnment<ch>:STATe
.............................................................. 111
[SENSe:]EFRontend<fe>:ALIGnment<ch>:TYPE
...............................................................111
[SENSe:]EFRontend<fe>:ALIGnment<ch>:VALid?
............................................................. 111
[SENSe:]EFRontend<fe>:ALIGnment<ch>?
Starts a selfalignment on the IF cable to the frontend and returns the result.
Suffix:
<fe>
.
1
Connected frontend
<ch>
1..n
Currently irrelevant
Return values:
<Result>
0
No error
Configuring the Measurement