Remote Commands for HRP UWB Measurements
R&S
®
VSE-K149
111
User Manual 1179.3315.02 ─ 01
[SENSe:]EFRontend<fe>:ALIGnment<ch>:STATe
<State>
Activates correction of the IF signal due to cable loss from the frontend to the analyzer.
Specify the file with correction data using
Suffix:
<fe>
.
1
Connected frontend
<ch>
1..n
Currently irrelevant
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
*RST:
0
[SENSe:]EFRontend<fe>:ALIGnment<ch>:TYPE
<Type>
Selects the type of frequency correction for the IF cable from the frontend to the ana-
lyzer.
Suffix:
<fe>
.
1
Connected frontend
<ch>
1..n
Currently irrelevant
Parameters:
<Type>
FILE | ADJustment
FILE
Frequency correction using the file specified with
]EFRontend<fe>:ALIGnment<ch>:FILE
ADJustment
Frequency correction using self-alignment data, see
[SENSe:]EFRontend<fe>:ALIGnment<ch>:VALid?
Queries whether the correction data file is valid.
Suffix:
<fe>
.
1
Connected frontend
Configuring the Measurement