Maintenance
95
User Manual | 2902.5569.01 - 03
System Disk Recovery
SpycerNode SC
Once the loading has finished, you will see the RuS Rescue script
with its options on the screen. Your display should look similar to the
following:
7.
To create a backup image of your system disk and save it to the USB
flash drive, press
[1]
and then
[Enter]
.
A list of possible source devices will be detailed on the screen. The
system disk normally is the ‘ATA’ disk with, for example, ‘sda’, ‘sdb’ or
‘sdc’ as its device name
(e.g.:
1:0:0:0
disk
ATA
<device info>
/dev/sda
).
8.
Enter the name of the system disk: Type in e.g.
sda
(or in other cases
sdb
,
sdc
, etc.) and press
[Enter]
.
The system will ask you to enter the image name for the backup
image to be saved to the USB flash drive. By entering the name of an
already existing backup image you can overwrite it.
9.
Type in the name of the image you want to save to the USB flash drive
for a later recovery. To confirm your entry press
[Enter]
.
The system will ask you to confirm your selection and whether you
want to continue:
If you do not perform any action, RuS Rescue will be loaded automatically af-
ter 30 seconds.
--- RuS Rescue ---
1 - Backup on internal USB device
2 - Restore from internal USB device
3 - Backup on self selected external device
4 - Restore from self selected external device
5 - Reboot the system
6 - Poweroff the system
0 - Exit
Enter selection:
Ex factory the SpycerNode SC will be delivered with ’sda’ as the default sys-
tem disk. If other configurations have been made later or on customer re-
quest, this may be different.
Data Loss
Selecting the wrong source device may lead to an
unwanted configuration and malfunctions when the system
is operating.
Continue with the following steps only if you are able to
identify the correct source device.
Summary of Contents for SpycerNode SC
Page 1: ...R S SpycerNode SC Storage Solution User Manual Version 03 2902 5569 02...
Page 10: ...General Appropriate Use SpycerNode SC 10 User Manual 2902 5569 01 03...
Page 28: ...Product Description The Rear of the System SpycerNode SC 28 User Manual 2902 5569 01 03...
Page 64: ...Installation Installing the Spectrum Scale Client SpycerNode SC 64 User Manual 2902 5569 01 03...
Page 76: ...Operation Shutting down the System SpycerNode SC 76 User Manual 2902 5569 01 03...
Page 106: ...Appendix CE Declaration of Conformity SpycerNode SC 106 User Manual 2902 5569 01 03...