R&S OSP
Getting Started
R&S OSP Panel Functions
Quick Start Guide 1505.3896.62 - 14
48
See also in the operating manual for a detailed description of the interface.
The module R&S OSP-B114 only contains one built-in DPDT relay and offers four
output lines. The other functions are the same as for the OSP-B104 module.
3.3.9.1 Setting the Transfer Relays
Clicking to the symbol of the relay, the position of each relay can be toggled individually. In
one position the connections are made between connectors 1 and 2 and between 3 and 4.
In the other position the connections are made between connectors 1 and 4 and between 2
and 3.
The buttons R1 up to R4 are not required for manual operation of the switches, but for
defining a path configuration (see
chapter 3.4
R1
Any button R1 up to R4 in grey color indicates that this relay is not selected. A non
selected relay is not considered when defining a path configuration.
R2
To take over particular relays into the path configuration, the relay buttons must be
selected by clicking on each of the relay buttons required. The selected relay is
displayed with a button in green color. All relays whose relay buttons are selected are
taken over into a path configuration.
Pressing the Shift key while clicking on a relay button will toggle between selecting all
relays of this module and deselecting all of them.
Summary of Contents for OSP-B011
Page 132: ......