Setting of Parameters
5 Setting of
Parameters
Three methods of setting signal parameters are offered:
numeric keypad, knob and the arrow buttons. Please use
the soft menu keys for selecting the respective menu item.
5.1 Numeric keypad
The simplest method of en-
tering parameters quickly
and exactly is the entry via
the numerical keyboard with
the number keys (0...9), the
decimal point key (.) and the
minus key (-). When entering
parameters via the keyboard
the value will be accepted
upon pushing the respective
unit key GHz (-dBm), MHz
(dBm), kHz (dB..) or Hz (dB..).
The keys have multiple as-
signments. Prior to pushing
any key an entry may be de-
leted by pushing the key BACK. During the operations the
window will remain open. The CANCEL key will termi-
nate the entry of parameters and close the window. In text
mode characters can be confirmed with the ENTER key.
5.2 Rotary knob
It is possible to only use the knob for all settings. Va-
lues can also be entered with the rotary knob. The entry
is changed in steps and the spectrum analyzer immedia-
tely sets the appropriate entry parameter. Turning the knob
B
19
20
21
22
Fig. 5.1: Section B with numeric
keypad, unit and command keys
CW will increase the value, turning
it CCW will decrease it. Such pa-
rameters can be modified only by
using the knob (for example display
settings).
5.3 Arrow buttons
The arrow buttons allow the Zoom-
In resp. Zoom-Out functionality.
The button will double the span,
the button will halve the span.
5.4 Interactive softkeys
The grey soft menu keys at the
righthand side of the screen are
used for the menu field displayed. Use the knob or the nu-
meric keypad for setting the parameter selected. If a menu
field was selected via the soft menu keys, this item will be
marked in blue, it is now activated for entering a parame-
ter. If an instrument function should not be available due
to a specific setting, the associated soft menu key will be
deactivated, the lettering will be shown in gray.
5.5 How to enter numerical values
❙Use the gray soft menu keys for the selection of a menu
item.
❙Enter the value of the parameter using the numerical
keyboard or modify it with the knob.
❙After a keyboard entry push the respective unit key.
Fig. 5.2:
Display segmentation in sweep modes
24
24
23
C
Fig. 5.3: Rotary knob with
arrow buttons
Summary of Contents for HMS-X
Page 82: ...82 Appendix ...
Page 83: ...83 Appendix ...