User Manual – EC II GSM SE
34
TLR:<Phone No>
Test alarm receiver
TLC:<Code>
Test alarm code
TLI:<AB>
Test alarm mode
A: 0 = test alarm off, 1 = test alarm on
B: 1-9 = test alarm interval (days)
TCR:<Phone No>
Technical alarm receiver - battery alarms
TCC:<Code>
Technical alarm code - battery alarms
SF1:<ABBCDEFFGH>
Special Functions 1 where ABBCDEFFGH is the
following:
A: 0 = NC alarm button of central unit
1 = NO alarm button of central unit
BB: 00-30 = alarm button delay in seconds
C: 0 = do not answer incoming calls
1 = always answer
2 = only answer after an alarm
D: 0 = alarm acknowledge on
1 = simple alarm acknowledge
2 = alarm acknowledge off
E: 0 = alarm filter input off
1 = alarm filter input active high
2 = alarm filter input active low
FF: 00-99 = alarm type for central unit
alarm input, ALBU1 & ALBU2
G: 0 = traditional flash sequence for LED
in speech unit and LED C
1 = flash sequence according to EN81:70
H: 0 = battery alarms are not dialed out
1 = battery alarms are dialed out
SF2:<IJJKKLMNO>
Special Functions 2 where IJJKKLMNO is the
following:
I: 0 = Relay activated by alarm button
1 = Relay remotely controlled
JJ: 00-99 alarm type for End-of-Alarm
KK: 00-99 alarm type for speech unit
alarm input
L: 0 = NC alarm button of speech unit
1 = NO alarm button of speech unit
M: 0 = Magnetic switch not active
1 = Magnetic switch active
N: 0 = CPC protocol
1 = P100 protocol
O: 0 = No alive flash in speech unit
1 = Alive flash in speech unit
*<comment>
Free-text comment
Table 1
Summary of Contents for EC II GSM SE
Page 1: ...EC II GSM SE User Manual...