User Manual – EC II GSM SE
30
Programming mode is automatically disconnected and the alarm is sent immediately. The
alarm is speech connecting. The alarm type is 28d but can be changed with the following pro-
gramming sequence:
<Alarm type>
The alarm type shall always be entered decimal and with two digits, 00-99. Note that this
alarm type is also used when the reed switch is activated. Default alarm type can be set with:
8.4.17 Magnetic switch
There is a hidden magnetic switch under the front plate, see pictures below.
Position of magnetic switch
It is activated with a strong magnet and at activation an end-of-alarm call is automatically
made. Note that it is only possible to use this functionality on speech units with front plates of
stainless steel. If the COP version is mounted behind a lift wall it is normally not possible to
activate the switch.
Deactivate the function of the magnetic switch with:
Activate the magnetic switch with the following programming sequence:
At activation a speech connected alarm is automatically made using the alarm type 28d. The
alarm type can be changed with the following programming sequence:
<Alarm type>
Note that this alarm type is also used for the end-of-alarm function described under section
8.4.16 above.
8.4.18 Disabling of “alive” flash in speech unit
When the lift phone is running and at rest the green LED in the speech unit is slowly flashing
to indicate that everything is in order. When connecting an external pictogram to the LED out-
Summary of Contents for EC II GSM SE