9.5 Checking the status of battery and test alarm
With a SMS it is possible to have important information about the product status according to
Picture 3 below. Every time the lift phone is restarted the status information is reset, except
the information about the software and if battery alarms are allowed to be called out or not.
That information is stored in the SIM card and remains there also after a restart.
Picture 3
SMS to lift phone
SMS from lift phone
For detailed information and an explanation of the different parameters, see Table 2 below.
The returned SMS in Picture 3 above should be read as follows:
The software application version is 2.2.1 and the firmware version is 655_09gg. It has been
up and running for 21 days, 10 hours and 13 minutes. The battery is on stand-by charge and
the current voltage is 12.123V. Battery alarms are allowed to be called out and a battery
alarm was sent 17 hours and 10 minutes ago. The battery alarm occurred 74 minutes in the
battery test at a voltage of 11.782V. A battery alarm is active. Latest test alarm was sent 53
minutes ago.
Parameter
Description
App:<version>
Application
Version for the application in use
FW:<version>
Firmware
Version for the firmware in use
Up:<dd:hh:mm>
Uptime
Total uptime
Pow:<XXXX>
Power
Power status, where XXXX can be any of the fol-
lowing:
START:
Startup mode
IDLE:
Stand by charge
TEST:
Battery test
CHARGE:
Forced charge
BATTERY:
Runs on battery
U:<voltage>
Current battery voltage
BAE:<Y/N>
Battery Alarms Enabled
1111
status
App:2.2.1
FW:655_09gg
Up:21d10h13m
Pow:IDLE.1
U:12.123
BAE:Y
BA:0d17h10m @74
11.782
BAS:alarm
TA:0d00h53m
Summary of Contents for EC II GSM SE