User Manual – EC II GSM SE
47
16 Programming overview
Below follows an overview of all programmable functions in EC II GSM SE. Please note that
the overview describes all current functionality where some are not available in earlier product
releases. Contact your local distributor or Rocom GmbH for more information.
The column marked “Def” shows the possible default setting marked with “X” or with the ac-
tual value. The column marked “Ref” shows which chapter in the manual where more informa-
tion about the function is found. The programming sequences that are necessary to make an
alarm are marked with gray color in the table below.
No.
Programming sequence
Function
Def
Ref
1.
< Phone No. >
Programming of phone number to
primary alarm receiver. Max 20 dig-
its
8.3.4
2.
< Phone No. >
Programming of phone number to
secondary alarm receiver. Max 20
digits
8.3.4
3.
Test of secondary alarm receiver
8.3.5
4.
< Alarm code 1 >
Programming of alarm code 1. Max
10 digits
8.3.4
5.
< Alarm code 2 >
Programming of alarm code 2. Max
10 digits. Alarm receivers 2-6 re-
ceive this alarm code.
8.3.4
6.
< 3-6 >
< Phone No. >
Programming of phone numbers to
alarm receiver 3 to 6. Max 20 digits
8.3.4
7.
< 3-6 >
Test of alarm receiver 3 to 6.
8.3.5
8.
Set alarm input in central unit to
Normally Open
8.3.3
9.
Set alarm input in central unit to
Normally Close
X
8.3.3
10.
Set alarm input in speech unit to
Normally Open
8.3.3
11.
Set alarm input in speech unit to
Normally Close
X
8.3.3
12.
< 1-30 >
Delay time to activate alarm inputs
on central unit and speech unit. Unit
in seconds.
5 sec
8.4.2
13.
Activation P100 protocol
8.4.19
Summary of Contents for EC II GSM SE
Page 1: ...EC II GSM SE User Manual...