92
Rockwell Automation Publication D2-3518-4 - January 2020
Chapter 9
Parameter Descriptions
Table 7 - Default Values for Preset Speeds 1...7
Specifies which input signal is being used as a trim input.
Specifies if Ref A speed reference or Ref B speed reference is to be trimmed.
Parameter No.
Parameter Name
Default
101
Preset Speed 1
5.0 Hz
102
Preset Speed 2
10.0 Hz
103
Preset Speed 3
20.0 Hz
104
Preset Speed 4
30.0 Hz
105
Preset Speed 5
40.0 Hz
106
Preset Speed 6
50.0 Hz
107
Preset Speed 7
60.0 Hz
117
Trim In Select
Range:
1 = Analog In 1
2 = Analog In 2
3...8 = Reserved
9 = MOP Level
10 = Reserved
11 = Preset Spd 1
12 = Preset Spd 2
13 = Preset Spd 3
14 = Preset Spd 4
15 = Preset Spd 5
16 = Preset Spd 6
17 = Preset Spd 7
18 = DPI Port 1
19 = DPI Port 2
20 = DPI Port 3
21 = DPI Port 4
22 = DPI Port 5
Default:
2 = Analog In 2
Access:
1
Path:
Speed Command > Speed Trim
See also:
90, 93
118
Trim Out Select
Range:
Default:
Access:
1
Path:
Speed Command > Speed Trim
See also:
117, 119, 120
Summary of Contents for Allen-Bradley LiquiFlo 2.0
Page 1: ...LiquiFlo 2 0 AC Drive User Manual OriginalInstructions ...
Page 6: ...6 Rockwell Automation Publication D2 3518 4 January 2020 Table of Contents Notes ...
Page 8: ...8 Rockwell Automation Publication D2 3518 4 January 2020 Preface Notes ...
Page 12: ...12 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 1 Introduction Notes ...
Page 34: ...34 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 2 About the Drive Notes ...
Page 68: ...68 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 8 Programming Basics Notes ...
Page 267: ......