178
Rockwell Automation Publication D2-3518-4 - January 2020
Chapter 9
Parameter Descriptions
Frame 3 drives (firmware version 1.x) only:
Figure 72 - Dig In Status (216) Frame 3
On the Frame 3 drive, AC Line I/O Digital Input 1 is used for precharge
contactor feedback.
• A
1
in bit 0 indicates that all of the precharge contactors are closed.
• A
0
in bit 0 indicates that at least one of the contactors is open.
Also on the Frame 3 drive, bit 9 indicates that AC line rotation has been
determined, bit 8 indicates whether the rotation is ACB (not usable) or ABC
(usable), and bits 10...15 provide information about the internal state of the AC
line synchronization function of the AC Line I/O board. Bits 10...15 are for
engineering use only.
On the Frame 3 drive, AC Line I/O Digital Inputs 3 and 4 are used to select
measurements to be displayed on the optional input voltage and current meters,
as described in
Table 13
.
Table 13 - AC Line I/O Digital Inputs 3 and 4 (Frame 3)
Dig. In 4
Dig. In 3
Selected Measurement
0 0
Iv,
Vst
0 1
Iw,
Vtr
1 0
Iu,
Vrs
1 1
Iu,
Vrs
0
0
0
0
x
x
x
x
x
x
0
0
1
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Input Active
0
0
0
0
0
0
0
=Input Not Active
x =Reserved
Bit #
AC Line I/O Dig. Input 1
AC Line I/O Dig. Input 2
AC Line I/O Dig. Input 3
AC Line I/O Dig. Input 4
ACB Rotation
Rotation Valid
Vab Ready
Vbc Ready
Vca Ready
Vca Edge
Nibble 1
Nibble 2
Nibble 3
Nibble 4
Summary of Contents for Allen-Bradley LiquiFlo 2.0
Page 1: ...LiquiFlo 2 0 AC Drive User Manual OriginalInstructions ...
Page 6: ...6 Rockwell Automation Publication D2 3518 4 January 2020 Table of Contents Notes ...
Page 8: ...8 Rockwell Automation Publication D2 3518 4 January 2020 Preface Notes ...
Page 12: ...12 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 1 Introduction Notes ...
Page 34: ...34 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 2 About the Drive Notes ...
Page 68: ...68 Rockwell Automation Publication D2 3518 4 January 2020 Chapter 8 Programming Basics Notes ...
Page 267: ......