5 Technical data
MANUAL TME400-VCF · EN04 · 2019 March 26th
78
5.1.2.2.
Pulse In measuring inputs (sensor 1 / 2)
Note
For Ex connection values, see approval
The cable length to the Wiegand sensor must not exceed 15 m. With use of an exter-
nal pressure transducer, this maximum length is limited to 3 m.
5.1.2.3.
Temperature input
The temperature sensor is connected at the factory; the Ex connection values are
met in this process.
Measuring
range
-20°C to 60°C
Resolution
± 0.2 °C
5.1.2.4.
Pressure transducer
The pressure sensor is connected at the factory; the Ex connection values are met in
this process.
Wika Tl-1
Measuring ranges (absolute pressure)
•
0.8 bar to 2.5 bar
•
0.8 bar to 6.0 bar
•
2.0 bar to 10.0 bar
•
4.0 bar to 20.0 bar
Accuracy (at reference conditions according to IEC 61298-1)
•
≤ ±0.25 % of span
Hauser
Not yet released.