1.4.2.10.
Pressure loss
The measuring points for determining pressure loss are 1 x DN upstream and down-
stream of the meter. The pressure loss is calculated according to the following for-
mula:
4
2
m
p
DN
Q
Z
p
=
where:
p pressure loss
[mbar]
Z
p
coefficient of pressure loss
[-]
operating density
[kg/m³]
Q
m
volume flow at measurement conditions
[m³/h]
DN nominal meter diameter
[mm]
Device type
Z
p
Turbine meter TME400
5040
Perforated plate straightener L1 according to ISO/DIN
3150
Perforate plate straightener L2 according to ISO/DIN
6300
Perforated plate straightener L3 according to ISO/DIN
9450
Perforated plate straightener LP-35 RMG standard
1260
Bend straightener RB 19 according to ISO/DIN
1260
The values for Z
p
are rough averages. The exact value is calculated from the pres-
sure loss, which is determined when testing the meter.