Nominal
diameter
Pressure classes Lubricating device
Lubricant require-
ment
DN25-DN150 All pressure classes
As necessary (see below) optional
small oil pump
(push-button operated)
Every 3 months
6 strokes
DN200
All pressure classes
Small oil pump
(push-button operated)
Every 3 months
6 strokes
DN250
PN10 to PN16
ANSI 150
DN250
PN25 to PN100
ANSI300 toANSI600
Large oil pump
(lever operated)
Every 3 months
2 strokes
> DN300
All pressure classes
Also observe the notice plate on the housing.
In unfavorable conditions, e.g. with an accumulation of water and hydrocarbon con-
densate, as well as dust-laden gases, more frequent lubrication is recommended,
even daily in extreme cases (e.g. with continuous condensate formation).
Note
Recommended lubricating oil:
Shell Tellus S2 MA 10 or another oil with 2 to 4°E at 25°C.