APPENDIX
MANUAL TME400-VCF · EN04 · 2019 March 26th
93
587 1
menu16 RW
D02
Temperature
Mode
E
Source for temperature mea-
surement
588 2
float
RW
D03
Temperature
Default
E
T-V
Default value for tempera-
ture
590 2
float
RW
D04
Temperature min
E
°C
Lowest valid temperature
592 2
float
RW
D05
Temperature max E
°C
Highest valid temperature
594 2
float
RW
D06
Temperature
Damping
E
T-D Damping temperature
MB
reg
Reg.
number
Data
type
MB
access
Coordinate Name
Access Unit Description
602 2
float
R
D11
Resistance
PT1000
A
Ohm
Resistance of PT1000 (cor-
rected)
604 2
float
R
D12
Resistance
PT1000 uncor.
A
Ohm
Resistance of PT1000 (un-
corrected)
606 2
float
R
D30
Temperature (un-
cor.)
A
°C
Temperature (uncoreected)
MB
reg
Reg.
number
Data
type
MB
access
Coordinate Name
Access Unit Description
616 2
float
RW
D35
Temperature tar-
get value 1
N
°C
Temperature target value 1
618 2
float
RW
D36
Temperature tar-
get value 2
N
°C
Temperature target value 2
620 2
float
RW
D37
Temperature tar-
get value 2
N
°C
Temperature target value 2
622 2
float
RW
D38
Temperature tar-
get value 2
N
°C
Temperature target value 2
MB
reg
Reg.
number
Data
type
MB
access
Coordinate Name
Access Unit Description
628 1
menu16 RW
D41
Temperature Corr.
Write
E
Write temp. correction fac-
tors f0/1
MB
reg
Reg.
number
Data
type
MB
access
Coordinate Name
Access Unit Description
633 2
float
R
E02
Compressibility
A
K
Compressibility (from AGA8,
etc.)
MB
reg
Reg.
number
Data
type
MB
access
Coordinate Name
Access Unit Description
639 1
menu16 RW
E05
Calculation Method
E
Calculation method for
compress.
640 2
float
RW
E06
Compressibility
Default
E
K-V
Deafult value compressi-
bility
642 2
float
RW
E07
Calorific Value
E
Hon Calorific value