4 Operation
MANUAL TME400-VCF · EN04 · 2019 March 26th
75
0
Off (default)
1
On
Z27
Sensor type 1
0
Reed sensor
1
Wiegand sensor (default)
2
External
Z28
Sensor type 2
Settings are possible, but only make sense in 2-channel operation.
Settings changed here have no effect in 1-channel operation,
0
Reed sensor
1
Wiegand sensor (default)
2
External
Z29
Volume unit
0
m3 (Default)
1
cf
Coor-
dinate
Name
Modbus
register
Modbus
access
Protec-
tion
Data
type
Min. Max.
Default Unit
Z04
X:Y maximum pulse er-
ror
775
W
E
unit16
1
10000
10
X
Z05
X:Y maximum pulse
776
W
E
unit16
1
10000
10000
Y
Z10
Error register 1
332
R
A
int16
-
-
*
Err
Z11
Error register 2
333
R
A
int16
-
-
*
Err
Z12
Status register 1
334
R
A
int16
-
-
*
Sta
Z13
Status register 2
335
R
A
int16
-
-
*
Sta
Z15
Code word release
777
W
N
unit16
1
9999
0
COD
Z16
Change code word
778
W
C
int16
1
9999
1234
C-V
Z17
Device type
779
W
E
menu16
0
3
0
Z24
Display active max.
780
W
N
menu16
0
2
0
Z25
Volume metering mode
781
W
E
menu16
0
7
0
Z26
Characteristic correction
782
W
E
menu16
0
1
0
Z27
Sensor type 1
783
W
E
menu16
0
2
1
Z28
Sensor type 2
784
W
E
menu16
0
2
1
Z29
Volume unit
785
W
E
menu16
0
1
0
Note
If the parameter is not dimensioned, the text in the "Unit" column is shown in
the display of the TME400 to the right under UNIT.