6 ERRORS
Manual ERZ2000-DI · EN1.2 · 2017, December 21st
111
76
M
48-2
Factory state
I am a device which has not been tested.
1
No
No
77
H
48-3
PT1 open circ.
Resistance measurement 1 shows open circuit
2
No
No
78
H
48-6
PT3 inp.param.
Resistance input 3 parameterization error
2
No
No
79
A
50-0
T<>GERG lim.
Temperature exceeds GERG limits
2
Yes
Yes
80
A
50-1
P<>GERG lim.
Pressure exceeds GERG limits
2
Yes
Yes
81
A
50-2
rd<>GERG lim.
Relative density exceeds GERG limits
2
Yes
Yes
82
A
50-3
CO2<>GERG lim.
Carbon dioxide exceeds GERG limits
2
Yes
Yes
83
A
50-4
N2<>GERG lim.
Nitrogen exceeds GERG limits
2
Yes
Yes
84
A
50-5
Hs<>GERG lim.
Superior calorific value exceeds GERG limits
2
Yes
Yes
85
A
50-6
H2<>GERG lim.
Hydrogen exceeds GERG limits
2
Yes
Yes
86
A
50-8
GERG iter.max
Maximum permissible GERG iterations exceeded
2
Yes
Yes
87
A
51-0
T<>AGA limit
Temperature exceeds AGA limits
2
Yes
Yes
88
A
51-1
P<>AGA limit
Pressure exceeds AGA limits
2
Yes
Yes
89
A
51-2
rd<>AGA limit
Relative density exceeds AGA limits
2
Yes
Yes
90
A
51-3
CO2<>AGA limit
Carbon dioxide exceeds AGA limits
2
Yes
Yes
91
A
51-4
N2<>AGA limit
Nitrogen exceeds AGA limits
2
Yes
Yes
92
A
51-5
Hs<>AGA limit
Superior calorific value exceeds AGA limits
2
Yes
Yes
93
A
51-7
AGA oth.errors
Other AGA errors
2
Yes
Yes
94
A
51-8
AGA-pi,tau
AGA interim result, pi,tau exceed limits
2
Yes
Yes
95
A
51-9
Interp.pt.probl.
Error during calculation of interpolation point
2
Yes
Yes
96
A
52-0
Q<Qmin
Flow rate at measurement conditions below minimum
2
Yes
No
97
A
52-1
Q>Qmax
Flow rate at measurement conditions exceeds maximum
2
Yes
No
98
W
52-4
Bus-ID<>12
Bus identification for remote data transmission
has not exactly 12 characters
1
No
No
99
W
52-5
RDT ID<>16
Remote data transmission identification
has not exactly 16 characters
1
No
No
100
M
54-0
Calibr. lock
Calibration lock is open
2
No
No
101
M
54-1
User lock
User lock is open
2
No
No
102
M
54-2
Revision
Revision switch is open
2
No
No
103
R
56-0
Chan. 1 fault
Pulse counting channel 1 implausible
1
No
No
104
R
56-1
Chan. 2 fault
Pulse counting channel 2 implausible
1
No
No
105
A
56-2
Tc/Tb comb.
Tc/Tb combination not permitted
1
No
No
106
H
56-3
CAN check
CAN bus plausibilization
1
No
No
107
H
56-5
Old time
Time immediately before time adjustment
1
No
No
108
H
56-6
New time
Time immediately after time adjustment
1
No
No
109
R
56-7
Power OFF
Supply voltage failure
1
No
No
110
W
60-0
Ethane<l.warn.lim.
Ethane below lower warning limit
2
Yes
Yes
111
W
60-1
Ethane>up.warn.lim.
Ethane exceeds upper warning limit
2
Yes
Yes
112
W
60-2
C3H8<l.warn.lim.
Propane below lower warning limit
2
Yes
Yes
113
W
60-3
C3H8>up.war.lim.
Propane exceeds upper warning limit
2
Yes
Yes
114
W
60-4
N-C4<l.warn.lim.
N-butane below lower warning limit
2
Yes
Yes
115
W
60-5
N-C4>up.warn.lim.
N-butane exceeds upper warning limit
2
Yes
Yes
116
W
60-6
I-C4<l.warn.lim.
I-butane below lower warning limit
2
Yes
Yes
117
W
60-7
I-C4>up.warn.lim.
I-butane exceeds upper warning limit
2
Yes
Yes