The conjunction of the device to the flue must be
as short as possible and must not have horizontal
or not much inclined parts. The counterslope parts
are forbidden and must be absolutely avoided.
Near the conjunction, inflammable materials must
not be present. The conjunction must not go inside
the flue. To increase the safety of the conjunction,
we suggest to install a washer on the wall being
sure that the connection between the washer and
the chimney is walled and well sealed. Also the
connection between the device and the conjunc-
tion must be fixed and sealed.
Wood fired cookers and thermal cookers are pre-
disposed to have flue outlets in different positions
(up, back, sides).
Before connecting the device to the chimney you
must be sure that all the outlets you will not use
are well closed. Eventually, you can make modifi-
cations using the devices given together with the
device.
2.8
CONJUNCTION OR FUME CONDUCT
2.9
FLUE OUTLET PREDISPOSITION
Picture 7 - Multiflue cooker/thermal cooker, predisposition of the correct flue outlet.
2.10
CORRECT CONJUNCTION TO THE CHIMNEY
If the conduct of the chimney starts from a lower
floor than the connection point of the device, it
may be necessary to close the conduct under the
connection pipe with fireproof materials. If you
have the chimney behind or up, you have to use
the connector with bayonet coupling. This must be
inserted and turned so that it can remain blocked.
This connector has a tolerance of about 1 cm to
make the installation easier. The tolerance is avail-
able according to a single direction which depends
on the orientation of the connector (see picture 8).