No. of parameters
2
Save changes
With
TDD1
Increment Trade Counter
Yes
Parameter Details
Parameter
Description
Range
Default
1
Linearisation point
1 .. 5
1
2
Test weight value without decimal point (none = cancel lin. of this
point)
0 .. 999999
-
Query Parameter Details
Parameter
Description
Range
1
Percentage of full scale reading (this value is given as integer - i.e. 24,999
is given as 24)
-100 .. 100
2
Correction (weight value without decimal point x10)
-100000 .. 100000
To clear one of the linearisation points leave the test weight value off.
Example: Scale Build is max1 = 500.0 kg, e1 = 0.1 kg
Command
Answer
Description
S01;
Select unit 1
LIC1;
0 CRLF
Clear linearisation point 1
LIC?1;
0,0 CRLF
No correction for point 1
MSV?;
120.5 CRLF
LIC1,1200;
0 CRLF
Set linearisation point 1 to correct for the current test weight of 120.0 kg.
(Note that weight is sent without any decimal point. So 400.0 kg is send as
4000 not 400.0)
LIC?1;
24,-50 CRLF
Current linearisation is approx. -0.5 kg at approx. 24% of fullscale reading
TDD1;
0 CRLF
Save setting
21.3.29
LIV: Setpoints
Set the parameters for the eight setpoints.
General
No. of parameters
12
Save changes
With
TDD1
Increment Trade Counter
No
Parameter Details
140
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...