Register
Name
Type
Write
Read
Read Response
Description
6351
PRINT BUFFER
STR(100)
PRT?1;
<
value
>
Print buffer
6401
PRINT SUPPLIED FORMAT
STR(246)
PRT,
<
value
>
;
Print using supplied format string
19.3
Modbus Input Registers
The following Modbus functions are implemented for input registers:
Read input registers (function code 0x04)
The following table lists the translation for each Modbus input register into the corresponding serial commu-
nication command:
Register
Name
Type
Write
Read
Read Response
Description
1
INPUT WEIGHT GROSS
SINT32
MSM?2;
<
value
>
Measured weight gross (equivalent of MSV)
3
INPUT WEIGHT NET
SINT32
MSM?3;
<
value
>
Measured weight net (equivalent of MSV)
5
INPUT WEIGHT DISPLAYED
SINT32
MSM?1;
<
value
>
Measured weight displayed (equivalent of MSV)
7
INPUT WEIGHT STATUS
UINT32
MSM?1;
,
<
value
>
Measured weight status (equivalent of MSV)
9
INPUT ERROR
UINT32
ESM?0;
<
value
>
Error status (equivalent of ESR)
101
C500-600-2.0.3