Parameter
Description
Range
Default
1
Analog output type
0 = Current output
1 = Voltage output
0 (Current output)
2
Analog output source
0 = Gross weight
1 = Net weight
2 = Displayed weight
3 = Comms control
2 (Displayed weight)
3
Zero adjustment
-2500 .. 2500
0
4
Span adjustment
-2500 .. 2500
0
5
Force analog output
0 = Normal operation
1 = Force output low
2 = Force output high
0 (Normal operation)
6
Absolute output
0 = Off
1 = On
0 (Off)
7
Clip output
0 = Off
1 = On
0 (Off)
Example
Command
Answer
Description
S01;
Select unit 1
AOC?;
0,2,0,0,0,0,0 CRLF
Get analog output settings
AOC,,,,2;
0 CRLF
Force analog output high
AOC,,,40;
0 CRLF
Change span adjustment
AOC,,,,0;
0 CRLF
Turn off force analog output high
TDD1;
0 CRLF
Save settings
21.3.5
ASF: Filtering
Set the filtering characteristics of a unit.
General
No. of parameters
2
Save changes
With
TDD1
Increment Trade Counter
No
Parameter Details
Parameter
Description
Range
Default
1
Number of consecutive readings to average
0 = 1
1 = 2
2 = 3
3 = 4
4 = 5
5 = 6
6 = 7
7 = 8
8 = 9
9 = 10
10 = 25
11 = 50
12 = 75
13 = 100
14 = 200
9
2
Anti-Jitter Setting
0 = off
1 = fine
2 = coarse
0
123
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...