background image

GENERAL DESCRIPTION

The  TS8010  Operator  Interface  Terminal  combines  unique  capabilities 

normally expected from high-end units with a very affordable price. It is built 

around a high performance core with integrated functionality.

The TS8010 is able to communicate with many different types of hardware 

using  high-speed  RS232/422/485  communications  ports  and  Ethernet  10  Base 

T/100 Base-TX communications. In addition, the TS8010 features USB for fast 

downloads  of  configuration  files  and  access  to  trending  and  data  logging.  A 

CompactFlash socket is provided so that Flash cards can be used to collect your 

trending and data logging information as well as to store larger configuration files.

In  addition  to  accessing  and  controlling  of  external  resources,  the TS8010 

allows a user to easily view and enter information. Users can enter data through 

the touchscreen or front panel 8-button keypad. 

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual  or  on  equipment  must  be  observed  to  ensure  personal  safety  and  to 

prevent  damage  to  either  the  instrument  or  equipment  connected  to  it.  If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Do  not  use  the  controller  to  directly  command  motors,  valves,  or  other 

actuators not equipped with safeguards. To do so can be potentially harmful to 

persons or equipment in the event of a fault to the controller.

CONTENTS OF PACKAGE

- TS8010 Operator Interface.

- Panel Gasket.

- This hardware bulletin.

- Template for panel cutout.

- Hardware packet for mounting unit into panel.

- Terminal block for connecting power.

ORDERING INFORMATION

DESCRIPTION

PART NUMBER

10.4" TFT VGA Display Operator Interface (indoor), USB 

Host, Isolated Comms

TS8010/00/02

CANopen Option Card

8000/CB/00/00

Profibus DP Option Card

8000/PB/00/00

DeviceNet Option Card

8000/DN/00/00

FireWire Option Card

8000/FA/00/00

MODEL TS8010 - 10.4" COLOR TOUCHSCREEN

CompactFlash is a registered trademark of CompactFlash Association.

  CONFIGURED USING DSI8000 SOFTWARE

  UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS 

(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1 

RS-422/485 ON OPTIONAL COMMUNICATIONS CARD)

  10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK 

UNITS AND HOST WEB PAGES

  USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION 

FROM A PC OR FOR DATA TRANSFERS TO A PC

  UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE 

MEMORY (32MBYTE FLASH)

  COMPACTFLASH

®

 SOCKET TO INCREASE MEMORY CAPACITY

  10.4-INCH TFT 32K VGA 640X480 PIXEL LCD

  OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE

  8-BUTTON KEYPAD FOR ON-SCREEN MENUS

  THREE FRONT PANEL LEDS

  POWER UNIT FROM 24VDC ±20% SUPPLY

  RESISTIVE ANALOG TOUCHSCREEN

CAUTION: Risk Of Danger.

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

WARNING - EXPLOSION HAZARD - SUBSTITUTION 

OF ANY COMPONENT MAY IMPAIR SUITABILITY 

FOR CLASS I, DIVISION 2

The protective conductor terminal is bonded to conductive 

parts  of  the  equipment  for  safety  purposes  and  must  be 

connected to an external protective earthing system.

1

Bulletin  HP471055U010
   

Issue 1.0

Drawing No.  LP0877X
Effective  10/11

Summary of Contents for TS8010

Page 1: ...OF PACKAGE TS8010 Operator Interface Panel Gasket This hardware bulletin Template for panel cutout Hardware packet for mounting unit into panel Terminal block for connecting power ORDERING INFORMATION DESCRIPTION PART NUMBER 10 4 TFT VGA Display Operator Interface indoor USB Host Isolated Comms TS8010 00 02 CANopen Option Card 8000 CB 00 00 Profibus DP Option Card 8000 PB 00 00 DeviceNet Option Ca...

Page 2: ...Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Vibration according to IEC 68 2 6 Operational 5 to 150 Hz in X Y Z direction for 1 5 hours 2 g Shock according to IEC 68 2 27 Operational 35 g 11 msec in 3 directions Altitude Up to 2000 meters 9 CERTIFICATIONS AND COMPLIANCES SAFETY IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement contro...

Page 3: ...terface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with an NEC Class 2 or...

Page 4: ...In order to access data from the CompactFlash card via the USB device port a driver must be installed on your computer This driver is installed with DSI8000 and is located in the folder C Program Files Parker DSI8000 Device after DSI8000 is installed This may have already been accomplished if your TS8010 was configured using the USB port Once the driver is installed connect the TS8010 to your PC w...

Page 5: ...N 6 COMM 3 COMM 1 TxB 5 B 2 TxA 4 A 5 DH485 COMMUNICATIONS The TS8010 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Parker SSD Drives TS to AB SLC 500 Connections RJ45 SSD Name RJ45 A B Name 1 TxB 1 A 2 TxA 2 B 3 8 RxA 24V 4 7 RxB ...

Page 6: ...uchscreen is fully functional as soon as the operator interface is initialized and can be operated with gloved hands TROUBLESHOOTING YOUR TS8010 If for any reason you have trouble operating connecting or simply have questions concerning your new TS8010 contact Parker SSD Drives technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL info us...

Page 7: ...isposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the TS8010 is a lithium type CR2025 BATTERY INVERTER TOP BOTTOM WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY WARNING EXPLOSION HAZARD DO NOT DISCONNECT E...

Page 8: ... CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending Information stored on a CompactFlash card by a TS8010 can be read by a card reader attached to a PC This information is stored in IBM Windows PC compatible FAT16 file format Note Do not remove or insert the Compac...

Reviews: