Register
Name
Type
Write
Read
Read Response
Description
3002
MSV FORMAT
UINT16
COF
<
value
>
;
COF?;
<
value
>
MSV output format
3011
HOUR
UINT16
CLK
<
value
>
;
CLK?;
<
value
>
Clock hour
3012
MINUTE
UINT16
CLK,
<
value
>
;
CLK?;
,
<
value
>
Clock minute
3013
SECOND
UINT16
CLK,,
<
value
>
;
CLK?;
,,
<
value
>
Clock second
3014
DAY
UINT16
CLK,,,
<
value
>
;
CLK?;
,,,
<
value
>
Clock day of month
3015
MONTH
UINT16
CLK,,,,
<
value
>
;
CLK?;
,,,,
<
value
>
Clock month
3016
YEAR
UINT16
CLK,,,,,
<
value
>
;
CLK?;
,,,,,
<
value
>
Clock year
3021
FULL PASS
UINT32
DPF
<
value
>
;
DPF?;
<
value
>
Full passcode
3023
SAFE PASS
UINT32
DPS
<
value
>
;
DPS?;
<
value
>
Safe passcode
3031
PERMIS KEY ZERO
UINT16
LBT0,
<
value
>
;
LBT?0;
<
value
>
Zero key permissions
3032
PERMIS KEY TARE
UINT16
LBT1,
<
value
>
;
LBT?1;
<
value
>
Tare key permissions
3033
PERMIS KEY GROSSNET
UINT16
LBT2,
<
value
>
;
LBT?2;
<
value
>
Gross/net key permissions
3034
PERMIS KEY FUNC1
UINT16
LBT3,
<
value
>
;
LBT?3;
<
value
>
Function key 1 permissions
3035
PERMIS KEY FUNC2
UINT16
LBT4,
<
value
>
;
LBT?4;
<
value
>
Function key 2 permissions
3036
PERMIS KEY FUNC3
UINT16
LBT5,
<
value
>
;
LBT?5;
<
value
>
Function key 3 permissions
3042
KEY REM1 FN
UINT16
RBT1,
<
value
>
;
RBT?1;
<
value
>
Remote button 1 function
3043
KEY REM2 FN
UINT16
RBT2,
<
value
>
;
RBT?2;
<
value
>
Remote button 2 function
3044
KEY REM3 FN
UINT16
RBT3,
<
value
>
;
RBT?3;
<
value
>
Remote button 3 function
3045
KEY REM4 FN
UINT16
RBT4,
<
value
>
;
RBT?4;
<
value
>
Remote button 4 function
3046
KEY REM5 FN
UINT16
RBT5,
<
value
>
;
RBT?5;
<
value
>
Remote button 5 function
3047
KEY REM6 FN
UINT16
RBT6,
<
value
>
;
RBT?6;
<
value
>
Remote button 6 function
3048
KEY REM7 FN
UINT16
RBT7,
<
value
>
;
RBT?7;
<
value
>
Remote button 7 function
3049
KEY REM8 FN
UINT16
RBT8,
<
value
>
;
RBT?8;
<
value
>
Remote button 8 function
3051
QA ENABLE
UINT16
QAF
<
value
>
;
QAF?;
<
value
>
Quality assurance enable
3052
QA DATE
UINT16
QAF,
<
value
>
;
QAF?;
,
<
value
>
Quality assurance day of month
3053
QA MONTH
UINT16
QAF,,
<
value
>
;
QAF?;
,,
<
value
>
Quality assurance month
3054
QA YEAR
UINT16
QAF,,,
<
value
>
;
QAF?;
,,,
<
value
>
Quality assurance year
3061
KEY FUNC1 FN
UINT16
FBT1,
<
value
>
;
FBT?1;
<
value
>
Function key 1 function
3062
KEY FUNC2 FN
UINT16
FBT2,
<
value
>
;
FBT?2;
<
value
>
Function key 2 function
3063
KEY FUNC3 FN
UINT16
FBT3,
<
value
>
;
FBT?3;
<
value
>
Function key 3 function
4001
USER ZERO
UINT16
CDL;
Perform User zero
4002
TARE
SINT32
TAR;
TAR?;
<
value
>
Perform semi-automatic tare
4004
SWITCH GROSS NET
UINT16
TAS
<
value
>
;
TAS?;
<
value
>
Switch gross and net
4005
PRESET TARE
SINT32
TAV
<
value
>
;
TAV?;
<
value
>
Perform preset tare
4101
DEFAULT USERDB
UINT16
DFT0;
Default user database
4102
DEFAULT RTDB
UINT16
DFT1;
Default runtime database
4103
DEFAULT CAL
UINT16
DFT2;
Default calibration
4104
DEFAULT ETH
UINT16
DFT3;
Default ethernet settings
4151
SAVE LOAD DEFAULT SETTINGS
UINT32
TDD
<
value
>
;
TDD?;
<
value
>
Save settings/load settings/set
defaults/read cal count
4201
DISPLAY
STR(32)
FPL?;
<
value
>
Read display buffer
4222
KEY REM1 PRESS
UINT16
RBT1,,
<
value
>
;
Remote button 1 press (0 short, 1
long)
4223
KEY REM2 PRESS
UINT16
RBT2,,
<
value
>
;
Remote button 2 press (0 short, 1
long)
4224
KEY REM3 PRESS
UINT16
RBT3,,
<
value
>
;
Remote button 3 press (0 short, 1
long)
4225
KEY REM4 PRESS
UINT16
RBT4,,
<
value
>
;
Remote button 4 press (0 short, 1
long)
4226
KEY REM5 PRESS
UINT16
RBT5,,
<
value
>
;
Remote button 5 press (0 short, 1
long)
4227
KEY REM6 PRESS
UINT16
RBT6,,
<
value
>
;
Remote button 6 press (0 short, 1
long)
4228
KEY REM7 PRESS
UINT16
RBT7,,
<
value
>
;
Remote button 7 press (0 short, 1
long)
4229
KEY REM8 PRESS
UINT16
RBT8,,
<
value
>
;
Remote button 8 press (0 short, 1
long)
4231
KEY ZERO
UINT16
FPL1,
<
value
>
;
Zero key press (0 short, 1 long)
4232
KEY TARE
UINT16
FPL2,
<
value
>
;
Tare key press (0 short, 1 long)
4233
KEY GROSSNET
UINT16
FPL3,
<
value
>
;
Gross/net key press (0 short, 1
long)
4234
KEY FUNC1
UINT16
FPL4,
<
value
>
;
Function 1 key press (0 short, 1
long)
4235
KEY FUNC2
UINT16
FPL5,
<
value
>
;
Function 2 key press (0 short, 1
long)
4236
KEY FUNC3
UINT16
FPL6,
<
value
>
;
Function 3 key press (0 short, 1
long)
4241
KEY FUNC1 PRESS
UINT16
FBT1,,
<
value
>
;
Function key 1 press (0 short, 1
long)
4242
KEY FUNC2 PRESS
UINT16
FBT2,,
<
value
>
;
Function key 2 press (0 short, 1
long)
98
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...