Valid for Africa, Asia, Europe, Latin America
,
South America
Q.PRO-G4.X · Q.PRO EC-G4.X · Q.PRO BFR-G4.X · Q.PLUS BFR-G4.X
INSTALLATION AND
OPERATION MANUAL
Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO G4 X Q PRO EC G4 X Q PRO BFR G4 X Q PLUS BFR G4 X INSTALLATION AND OPERATION MANUAL...
Page 2: ...possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer a...
Page 3: ...xt of accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for any other sys tem components that may be part of t...
Page 4: ...expansion and contraction due to temperature fluctuations Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ensure that the clamps and the m...
Page 5: ...of module and middle of the clamp Describes the maximum module surface load vertical to the module surface regarding safety factors e g EUROCODE For this purpose the load value determined by load tes...
Page 6: ...y module defects ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is met In order to limit reverse currents that may occur we reco...
Page 7: ...modules NOTE Module damage may occur Do not install modules near flammable gas vapors Do not install modules in close proximity to air conditioning systems 3 1 Safety and transport 3 INSTALLATION DAN...
Page 8: ...can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit voltage is active even at low levels of solar...
Page 9: ...ropriate and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Use solar cables for th...
Page 10: ...NECTION Protective Grounding The modules must be grounded in accordance with the local statutory regulations Functional grounding When using an installation tilt of 5 a functional grounding at the neg...
Page 11: ...area alone or without taking adequate security precautions Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Remove snow and ice carefully without...
Page 12: ...Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installa...