INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

18

 

Ä

Ensure that all necessary safety and 
functional tests have been carried out 
according to current industry standards.

NOTE

! Module damage may occur!

 

Ä

Ensure that the plug connections are 
secured away from any water-channelling 
surface.  

 

Ä

Integrate the system into the existing 
lightening protection system in 
accordance with the applicable local 
regulations.

WARNING

! Fire Risk!

 

Ä

Do not use light concentrators (e.g. 

mirrors or lenses).

 

Ä

Ensure that the cabling is not exposed 
and/or hanging and is protected from dirt 
and moisture.

4.4  After installation

ELECTRICAL CONNECTION

Protective Grounding

 

Ä

The modules must be grounded in accordance with the 
local statutory regulations.

Functional grounding

• 

When using an installation tilt of < 5° a functional 
grounding at the negative generator conncetion must 
be implemented.

 

Ä

Ensure that the difference of potential between the 

negative generator connection and the PE(N) of every 

MPP tracker of the respective inverters is 0 V.

 

Ä

Follow the directions of the inverter manufacturer.

 

Ä

Only use inverters which include lincensed grounding 
kits.

5       GROUNDING

DANGER!  
Risk of fatal injury due to electric shock!

 

Ä

Do not attempt to fix any problems yourself (e.g., 
glass cracks, damaged cables).

 

Ä

Please contact an installer or Q CELLS Technical 
Customer Service Department.

FAULTS AND DEFECTS

 

Ä

Do not disconnect modules by yourself.

 

Ä

Please contact an installer or Q CELLS Technical 
Customer Service Department.

 

Ä

Dispose of modules in accordance with the local disposal 
regulations.

7 DISPOSAL

Summary of Contents for Q.PRO-G4.X

Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO G4 X Q PRO EC G4 X Q PRO BFR G4 X Q PLUS BFR G4 X INSTALLATION AND OPERATION MANUAL...

Page 2: ...possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer a...

Page 3: ...xt of accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for any other sys tem components that may be part of t...

Page 4: ...expansion and contraction due to temperature fluctuations Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ensure that the clamps and the m...

Page 5: ...of module and middle of the clamp Describes the maximum module surface load vertical to the module surface regarding safety factors e g EUROCODE For this purpose the load value determined by load tes...

Page 6: ...y module defects ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is met In order to limit reverse currents that may occur we reco...

Page 7: ...modules NOTE Module damage may occur Do not install modules near flammable gas vapors Do not install modules in close proximity to air conditioning systems 3 1 Safety and transport 3 INSTALLATION DAN...

Page 8: ...can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit voltage is active even at low levels of solar...

Page 9: ...ropriate and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Use solar cables for th...

Page 10: ...NECTION Protective Grounding The modules must be grounded in accordance with the local statutory regulations Functional grounding When using an installation tilt of 5 a functional grounding at the neg...

Page 11: ...area alone or without taking adequate security precautions Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Remove snow and ice carefully without...

Page 12: ...Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installa...

Reviews: