INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

17

16

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure correct polarity.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Be sure to maintain the time intervals as 

specified by the inverter manufacturer 

between switching off the inverter and 
beginning any further work.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Never unplug the cable when under load.

1.

 Switch off the inverter.

OFF

EN

3.

 Switch off the DC circuit breaker.

 

Ä

Disconnect plugs by the use of 

appropriate and qualified tools of 

the manufacturer Tyco, Amphenol or 
Multicontact.

2.

 Cover the modules to be disconnected.

4.2  Electrical installation safety

ELECTRICAL CONNECTION

 

Ä

Use solar cables for the connection at 
the junction box outlet. 

 

Ä

Use the same, inverter-compatible plugs.

SOLAR

NOTE

! Module damage may occur!

 

Ä

Ensure that the cabling is not under 
stress.

 

Ä

Ensure that the cables do not run 
between module and subconstruction 

(danger of pinch).

 

Ä

Do not connect modules with different 
orientations or angles of inclination in 
the same string.

 

Ä

Ensure for a tight connection between 
the plugs. Plugs click together audibly.

Klick

DE

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure that all electrical components are 
in a proper, dry, and safe condition.

• 

Standard wiring with a return cable.

Inverter

EN

4.3  Connection of modules

ELECTRICAL CONNECTION

Summary of Contents for Q.PRO-G4.X

Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO G4 X Q PRO EC G4 X Q PRO BFR G4 X Q PLUS BFR G4 X INSTALLATION AND OPERATION MANUAL...

Page 2: ...possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer a...

Page 3: ...xt of accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for any other sys tem components that may be part of t...

Page 4: ...expansion and contraction due to temperature fluctuations Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ensure that the clamps and the m...

Page 5: ...of module and middle of the clamp Describes the maximum module surface load vertical to the module surface regarding safety factors e g EUROCODE For this purpose the load value determined by load tes...

Page 6: ...y module defects ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is met In order to limit reverse currents that may occur we reco...

Page 7: ...modules NOTE Module damage may occur Do not install modules near flammable gas vapors Do not install modules in close proximity to air conditioning systems 3 1 Safety and transport 3 INSTALLATION DAN...

Page 8: ...can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit voltage is active even at low levels of solar...

Page 9: ...ropriate and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Use solar cables for th...

Page 10: ...NECTION Protective Grounding The modules must be grounded in accordance with the local statutory regulations Functional grounding When using an installation tilt of 5 a functional grounding at the neg...

Page 11: ...area alone or without taking adequate security precautions Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Remove snow and ice carefully without...

Page 12: ...Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installa...

Reviews: