Register
Name
Type
Write
Read
Read Response
Description
5191
SP5 LOCK
UINT16
LIV5,,,,,,,,
<
value
>
;
LIV?5;
5,,,,,,,,
<
value
>
Setpoint 5 lock
5192
SP5 ALARM
UINT16
LIV5,,,,,,,,,
<
value
>
;
LIV?5;
5,,,,,,,,,
<
value
>
Setpoint 5 alarm
5193
SP5 TIMING
UINT16
LIV5,,,,,,,,,,
<
value
>
;
LIV?5;
5,,,,,,,,,,
<
value
>
Setpoint 5 timing
5194
SP5 RESET
UINT16
LIV5,,,,,,,,,,,
<
value
>
;
LIV?5;
5,,,,,,,,,,,
<
value
>
Setpoint 5 reset
5201
SP6 TYPE
UINT16
LIV6,
<
value
>
;
LIV?6;
6,
<
value
>
Setpoint 6 type
5202
SP6 SOURCE
UINT16
LIV6,,
<
value
>
;
LIV?6;
6,,
<
value
>
Setpoint 6 source
5204
SP6 TARGET
SINT32
LIV6,,,,
<
value
>
;
LIV?6;
6,,,,
<
value
>
Setpoint 6 target
5206
SP6 INFLIGHT
SINT32
LIV6,,,,,
<
value
>
;
LIV?6;
6,,,,,
<
value
>
Setpoint 6 inflight
5208
SP6 HYSTERESIS
SINT32
LIV6,,,,,,
<
value
>
;
LIV?6;
6,,,,,,
<
value
>
Setpoint 6 hysteresis
5210
SP6 LOGIC
UINT16
LIV6,,,,,,,
<
value
>
;
LIV?6;
6,,,,,,,
<
value
>
Setpoint 6 logic inversion
5211
SP6 LOCK
UINT16
LIV6,,,,,,,,
<
value
>
;
LIV?6;
6,,,,,,,,
<
value
>
Setpoint 6 lock
5212
SP6 ALARM
UINT16
LIV6,,,,,,,,,
<
value
>
;
LIV?6;
6,,,,,,,,,
<
value
>
Setpoint 6 alarm
5213
SP6 TIMING
UINT16
LIV6,,,,,,,,,,
<
value
>
;
LIV?6;
6,,,,,,,,,,
<
value
>
Setpoint 6 timing
5214
SP6 RESET
UINT16
LIV6,,,,,,,,,,,
<
value
>
;
LIV?6;
6,,,,,,,,,,,
<
value
>
Setpoint 6 reset
5221
SP7 TYPE
UINT16
LIV7,
<
value
>
;
LIV?7;
7,
<
value
>
Setpoint 7 type
5222
SP7 SOURCE
UINT16
LIV7,,
<
value
>
;
LIV?7;
7,,
<
value
>
Setpoint 7 source
5224
SP7 TARGET
SINT32
LIV7,,,,
<
value
>
;
LIV?7;
7,,,,
<
value
>
Setpoint 7 target
5226
SP7 INFLIGHT
SINT32
LIV7,,,,,
<
value
>
;
LIV?7;
7,,,,,
<
value
>
Setpoint 7 inflight
5228
SP7 HYSTERESIS
SINT32
LIV7,,,,,,
<
value
>
;
LIV?7;
7,,,,,,
<
value
>
Setpoint 7 hysteresis
5230
SP7 LOGIC
UINT16
LIV7,,,,,,,
<
value
>
;
LIV?7;
7,,,,,,,
<
value
>
Setpoint 7 logic inversion
5231
SP7 LOCK
UINT16
LIV7,,,,,,,,
<
value
>
;
LIV?7;
7,,,,,,,,
<
value
>
Setpoint 7 lock
5232
SP7 ALARM
UINT16
LIV7,,,,,,,,,
<
value
>
;
LIV?7;
7,,,,,,,,,
<
value
>
Setpoint 7 alarm
5233
SP7 TIMING
UINT16
LIV7,,,,,,,,,,
<
value
>
;
LIV?7;
7,,,,,,,,,,
<
value
>
Setpoint 7 timing
5234
SP7 RESET
UINT16
LIV7,,,,,,,,,,,
<
value
>
;
LIV?7;
7,,,,,,,,,,,
<
value
>
Setpoint 7 reset
5241
SP8 TYPE
UINT16
LIV8,
<
value
>
;
LIV?8;
8,
<
value
>
Setpoint 8 type
5242
SP8 SOURCE
UINT16
LIV8,,
<
value
>
;
LIV?8;
8,,
<
value
>
Setpoint 8 source
5244
SP8 TARGET
SINT32
LIV8,,,,
<
value
>
;
LIV?8;
8,,,,
<
value
>
Setpoint 8 target
5246
SP8 INFLIGHT
SINT32
LIV8,,,,,
<
value
>
;
LIV?8;
8,,,,,
<
value
>
Setpoint 8 inflight
5248
SP8 HYSTERESIS
SINT32
LIV8,,,,,,
<
value
>
;
LIV?8;
8,,,,,,
<
value
>
Setpoint 8 hysteresis
5250
SP8 LOGIC
UINT16
LIV8,,,,,,,
<
value
>
;
LIV?8;
8,,,,,,,
<
value
>
Setpoint 8 logic inversion
5251
SP8 LOCK
UINT16
LIV8,,,,,,,,
<
value
>
;
LIV?8;
8,,,,,,,,
<
value
>
Setpoint 8 lock
5252
SP8 ALARM
UINT16
LIV8,,,,,,,,,
<
value
>
;
LIV?8;
8,,,,,,,,,
<
value
>
Setpoint 8 alarm
5253
SP8 TIMING
UINT16
LIV8,,,,,,,,,,
<
value
>
;
LIV?8;
8,,,,,,,,,,
<
value
>
Setpoint 8 timing
5254
SP8 RESET
UINT16
LIV8,,,,,,,,,,,
<
value
>
;
LIV?8;
8,,,,,,,,,,,
<
value
>
Setpoint 8 reset
6001
ERROR SYS
UINT32
ESM?0;
<
value
>
Error status system (equivalent of
ESR)
6003
ERROR LATCH
UINT32
ESM?1;
<
value
>
Error status latched (equivalent
of ESR)
6101
UNIT ID
STR(15)
IDM
<
value
>
;
IDM?;
<
value
>
Unit identification (equivalent of
IDN)
6109
SERIAL NO
UINT32
IDM?;
,
<
value
>
Unit serial number (equivalent of
IDN)
6111
SW VERSION
STR(10)
IDM?;
,,
<
value
>
Unit software version (equivalent
of IDN)
6116
UNIT MODEL
STR(7)
IDM?;
,,,
<
value
>
Unit model (equivalent of IDN)
6201
WEIGHT DISPLAYED
SINT32
MSM?1;
<
value
>
Measured displayed weight
(equivalent of MSV)
6203
WEIGHT STATUS DISPLAYED
UINT32
MSM?1;
,
<
value
>
Measured displayed weight status
6205
WEIGHT GROSS
SINT32
MSM?2;
<
value
>
Measured gross weight (equivalent
of MSV)
6207
WEIGHT STATUS GROSS
UINT32
MSM?2;
,
<
value
>
Measured gross weight status
6209
WEIGHT NET
SINT32
MSM?3;
<
value
>
Measured net weight (equivalent
of MSV)
6211
WEIGHT STATUS NET
UINT32
MSM?3;
,
<
value
>
Measured net weight status
6213
WEIGHT TOTAL ITEMS
SINT32
MSM?4;
<
value
>
Measured total number of items
(equivalent of MSV)
6215
WEIGHT STATUS TOTAL ITEMS
UINT32
MSM?4;
,
<
value
>
Measured total number of items
weight status
6217
WEIGHT TOTAL
SINT32
MSM?5;
<
value
>
Measured total weight (equivalent
of MSV)
6219
WEIGHT STATUS TOTAL
UINT32
MSM?5;
,
<
value
>
Measured total weight status
6221
WEIGHT PEAK MAX
SINT32
MSM?6;
<
value
>
Measured peak maximum weight
(equivalent of MSV)
6223
WEIGHT STATUS PEAK MAX
UINT32
MSM?6;
,
<
value
>
Measured peak maximum weight
status
6225
WEIGHT LIVEWEIGH
SINT32
MSM?7;
<
value
>
Measured live weigh weight
(equivalent of MSV)
6227
WEIGHT STATUS LIVEWEIGH
UINT32
MSM?7;
,
<
value
>
Measured live weigh status
6251
MILLI VOLT PER VOLT
SINT32
VAL?;
<
value
>
Millivolt per volt reading
6301
PRINT ID
UINT32
PRT?0;
<
value
>
Print ID
6303
UINT16
PRT;
Print standard printout
100
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...