The “Simple Operation” connection can then be used to tare the indicator. Set
SimpleOp Command Out
to 2
(from the simple operations table in Section 20.3.3) to perform the tare.
Displayed Weight
is now 0 and the
Status Bit NET
is set.
To switch back to gross weight, first set the
SimpleOp Command Out
to 0. Then set
SimpleOp Command Out
to
4 to toggle gross/net.
Displayed Weight
is now 1500 and the
Status Bit NET
is not set.