Name
Address
Type
R
W
Description
Setpoint 7 Reset
A4D1
H
uint8
A
A
Setpoint 7 rest:
0 is none
1 is reset A
2 is reset B.
Setpoint 8 type
A4E1
H
uint8
A
A
Set setpoint 8 type:
0 is off
1 is on
2 is over
3 is under
4 is centre of zero
5 is zero band
6 is net
7 is motion
8 is error
9 is buzzer
10 is weigh out
11 is weigh in.
Setpoint 8 lock
A4E2
H
uint8
A
A
Set setpoint 8 lock:
0 is off
1 is on.
Setpoint 8 logic
A4E3
H
uint8
A
A
Set setpoint 8 logic:
0 is high
1 is low.
Setpoint 8 alarm
A4E4
H
uint8
A
A
Set setpoint 8 alarm:
0 is none
1 is single beep
2 is double beep
3 is continuous beeping
4 is flash the display.
Setpoint 8 source
A4E6
H
uint8
A
A
Set setpoint 8 source:
0 is gross weight
1 is net weight.
Setpoint 8 Target
A4E8
H
int32
A
A
Set setpoint 8 target.
Setpoint 8 Hysteresis
A4E9
H
int32
A
A
Set setpoint 8 hysteresis.
Setpoint 8 in flight
A4EA
H
int32
A
A
Set setpoint 8 in flight.
Setpoint 8 Timing
A4F0
H
uint8
A
A
Setpoint 8 timing:
0 is level
1 is edge
2 is latch
3 is pulse.
Setpoint 8 Reset
A4F1
H
uint8
A
A
Setpoint 8 rest:
0 is none
1 is reset A
2 is reset B.
Analogue output type
A801
H
uint8
A
A
Set the analogue output type:
0 is current
1 is voltage.
Analogue output absolute
A803
H
uint8
A
A
Set if analogue output follows the actual
weight value or the absolute value:
0 is actual value
1 is absolute value.
93
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...