35
PPoossiittiioonniinngg
The installation has been implemented by qualified technical
personnel only and that the instructions contained in the present
manual and the local regulations in force have been adhered to.
Choose the installation place according to the following criteria:
•
customer approval
•
safe accessible position
•
guarantee good unit operation
•
enough space for installation and maintenance shall be
preserved.
•
make sure that there
’
s no obstacle around the unit
•
the base surface should to bear the weight of the unit and
suitable for installing the unit without increasing noise or
vibration
•
carry out maintenance operations
•
technical spaces requested by the unit
•
water connections
•
max. distance allowed by the electrical connections
•
max. distance allowed by the refrigeranting connections
•
control points with capacity adequate to the unit weight
•
verify that all bearing points are aligned and leveled
•
sound levels (TECHNICAL INFORMATION section) external unit
M
Maaxxiim
muum
m ddiissttaannccee
Refrigerant pipes
SSiizzee
HHSS000044 -- HHSS001166
Refrigerant pipe min/max equivalent
length
A m
3 - 30
Maximum refrigerant pipe height
difference with outdoor unit higher
than indoors unit
B m
25
Maximum refrigerant pipe height
difference with outdoor unit underthan
indoor unit.
B m
25
inStaLLation RequiRementS