![Rinnai EHP-HS004MR32-EX2 User'S And Installer'S Manual Download Page 127](http://html1.mh-extra.com/html/rinnai/ehp-hs004mr32-ex2/ehp-hs004mr32-ex2_users-and-installers-manual_1462691127.webp)
127
1015
T5
Tank tem. unit:°C. read = real invalid: 0x7F
1016
Ta
Indoor air tem. unit:°C. read = real invalid: 0x7F
1017
Tbt1
Unit inertial storage tank temperature:°C. read = real invalid: 0x7F
1018
Tbt2
Unit additional storage tank temperature:°C. read = real invalid:
0x7F
1019
Water flow
Read=real* 100 unit: M3/H
1020
Unit type
10-18: means 10-18KW (second generation machines active)
1021
Unit target frequency
1022
Software version
1~99 means IDU software version
1023
High bit of capacity
1024
Low bit of capacity
1025
IDU capacity
Read = real *100 unit: Kw
1026
Fan rpm
Rpm, read = real
1027
PMV
ODU EXV opening, unit: Paulse. R & lt READ = REAL (show only 8
multiples Only Multiples of 8 Will BE Shown )
1028
T3
Coil temp., unit:°C.
1029
T4
Ambient temperature, unit:°C.
1030
Tp
Discharge Tp, unit:°C.
1031
Th
Suction tem. unit:°C.
1032
TF
Unit (°C) ---- Outside machine feedback invalid value 0x7F
1033
Pressure 1
ODU high pressure, unit: kPA . read = real
1034
Pressure 2
ODU low pressure, unit: kPA . read = real (Reserved)
1035
DC bus current
Unit: ampere
1036
DC bus voltage
Read = real (unit: V)
1037
ODU current
Operation current, unit A, read = real
1038
ODU voltage
Voltage, unit: V, read = real
1039
ODU frequency limitation solution
Solution ----- read from ODU 174
1040
High bit of electrical computation
1041
Low bit of electrical computation
1042
ODU software version
contRoL