![Rinnai EHP-HS004MR32-EX2 User'S And Installer'S Manual Download Page 156](http://html1.mh-extra.com/html/rinnai/ehp-hs004mr32-ex2/ehp-hs004mr32-ex2_users-and-installers-manual_1462691156.webp)
156
HHyyddrraauulliicc ddaattaa -- IInnddoooorr uunniitt ++ O
Ouuttddoooorr uunniitt
CCoonnssttrruuccttiioonn -- IInnddoooorr uunniitt
1 Sufficient volume up to a maximum of 60 litres of system water content.
2 The installation of the sanitary side safety valve is mandatory and left to the installer.
3 The installation of the fixture
’
s expansion tank is mandatory and is to be completed by the installer. The indicated volumes are for
reference purposes only..
SSiizzee
AA -- 119900 LL
AA -- 225500 LL
BB -- 225500 LL
SSyysstteem
m cchhaarraacctteerriissttiiccss
Maximum circuit pressure
bar
3,0
3,0
3,0
System expansion tank
1
l
8,0
8,0
8,0
Expansion vessel pre-charge
bar
1,0
1,0
1,0
System water connections
inch
1''
1''
1''
SSaanniittaarryy cchhaarraacctteerriissttiiccss
Tank type
Vitrified steel
Domestic hot water tank volume
l
190
250
250
Internal coil exchange surface
m
2
2,0
2,0
2,0
Storage dispersion
W/K ( kWh/24h)
1.81 (1.95)
2.04 (2.20)
2.04 (2.20)
Sanitary safety electric heater
kW
2,0
2,0
2,0
Maximum sanitary circuit pressure
2
bar
10,0
10,0
10,0
Recommended sanitary expansion vessel 3
l
12,0
16,0
16,0
Sanitary water connections
inch
3/4''
3/4''
3/4''
DDiim
meennssiioonnss
Operating (L x P x A)
mm
600 x 615 x 1774
600 x 615 x 2084
600 x 615 x 2084
Package (L x P x A)
mm
660 x 690 x 1890
660 x 690 x 2190
660 x 690 x 2190
Operation weight
kg
359
419
421
Shipping weight
kg
187
192
194
1 Consider the water content of the area with less volume
2 Time required to bring the water volume of the tank from a temperature of 10°C to a temperature of 50°C
3 Energy consumption to bring the water volume of the tank from a temperature of 10°C to a temperature of 50°C
SSiizzee
HHSS000044
HHSS000066
HHSS000088
HHSS001100
HHSS001122 HHSS001144 HHSS001166
CChhaarraacctteerriissttiiccss
190 L
250 L 190 L 250 L 190 L 250 L 190 L 250 L 250 L 250 L 250 L
Minimum system water
content
1
l
15
22
28
35
40
40
40
Minimum admitted water
flow rate
l/s
0,16
0,16
0,16
0,16
0,16
0,16
0,16
Maximum admitted water
flow rate
l/s
0,61
0,86
0,61
0,86
0,61
0,86
0,61
0,86
0,92
0,92
0,92
Net boiler capacity
l
182
240
182
240
182
240
182
240
240
240
240
DHW tank setpoint
°C
50
50
50
50
50
50
50
50
50
50
50
Water mixed at 40°C (V40)
l
204
269
204
269
204
269
204
269
269
269
269
Warm-up time
2 h:min
02:30
02:25 02:30 02:25 02:08 02:05 02:08 02:05 01:46 01:46
01:46
Energy consumption during
heating
3 kWh
2,20
2,70
2,20
2,70
2,30
2,85
2,30
2,85
3,01
3,01
3,01
technicaL data